Power source | 1Phase, 220 - 240V, 50Hz | ||||
Nominal cooling capacity (Min~Max) | kW | 6.0(1.8~7.5) | |||
Nominal heating capacity (Min~Max) | kW | 6.8(1.5~7.8) | |||
Power consumption | Cooling/Heating | kW | 1.43(0.50~2.39) / 1.45(0.60~3.00) | ||
EER/COP | Cooling/Heating | 4.20 / 4.69 | |||
Max. running current | A | 17 | |||
Sound power level | Cooling | dB(A) | 63 | ||
Heating | 65 | ||||
Sound pressure level | Cooling | dB(A) | 50 | ||
Heating | 52 | ||||
Air flow | Cooling | m3/min | 42.0 | ||
Heating | 42.0 | ||||
Exterior Dimensions | Height x Width x Depth | mm | 640 ×850(+65) ×290 | ||
Net weight | kg | 49.5 | |||
Refrigerant | Type/GWP | R410A/2088 | |||
Charge | kg/TCO2Eq | 2.5/5.22 | |||
Refrigerant piping size | Liquid/Gas | ø mm | 6.35(1/4") ×3 / 9.52(3/8") ×3 | ||
Outdoor operating temperature range | Cooling | °C | -15~43 | ||
Heating | -15~24 | ||||
Number of Connectable indoor units | Min.2~Max.3 | ||||
Total indoor units capacity | 11.0 |
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• In case of SRK71ZR + SRK71ZR, 2 Indoor units can be connectable. The total connecting capacity of indoor units should be between 100 ~ 160.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• In case of SRK71ZR + SRK71ZR, 2 Indoor units can be connectable. The total connecting capacity of indoor units should be between 100 ~ 160.