Nominal cooling capacity: 5.0(1.7~7.1) - Multi Outdoor Unit RAC

SCM50ZS-W

Multi Outdoor Unit RAC

Nominal cooling capacity of 5.0kW

Power source1Phase, 220 - 240V, 50Hz
Nominal cooling capacity (Min~Max)kW5.0(1.7~7.1)
Nominal heating capacity (Min~Max)kW6.0(1.0~7.5)
Power consumptionCooling/HeatingkW1.02(0.43~2.15) / 1.16(0.32~2.50)
EER/COPCooling/Heating4.90 / 5.17
Max. running currentA15
Sound power
level
CoolingdB(A)62
Heating64
Sound pressure
level
CoolingdB(A)49
Heating52
Air flowCoolingm3/min41.0
Heating41.0
Exterior DimensionsHeight x Width x Depthmm640×850(+65)×290
Net weightkg48.5
RefrigerantType/GWPR32/675
Chargekg/TCO2Eq1.8/1.215
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 9.52(3/8")
Outdoor operating
temperature range
Cooling°C-15~46
Heating-15~24
Number of Connectable indoor unitsMin.2~Max.3
Total indoor units capacity8.5
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• In case of SRK71ZR + SRK71ZR, 2 Indoor units can be connectable. The total connecting capacity of indoor units should be between 100 ~ 160.