SCM100ZS-W

Nominal cooling capacity: 10.0 (1.7~11.5) - Multi Outdoor Unit RAC

SCM100ZS-W

Multi Outdoor Unit RAC

Nominal cooling capacity of
10.0kW

Power source 1 Phase, 220 - 240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 10.0 (1.7~11.5)
Nominal heating capacity (Min~Max) kW 10.5 (0.9~11.5)
Power consumption Cooling/Heating kW 2.70 ( 0.48~3.65 ) / 2.38 ( 0.37~2.90 )
EER/COP Cooling/Heating 3.70 / 4.41
Max. running current A 21
Sound power
level
Cooling dB(A) 67
Heating 72
Sound pressure
level
Cooling dB(A) 54
Heating 59
Air flow Cooling m3/min 75.0
Heating 75.0
Exterior Dimensions Height x Width x Depth mm 945 x 970 x 370
Net weight kg 73
Refrigerant Type/GWP R32/675
Charge kg/TCO2Eq 2.98/2.012
Refrigerant piping size Liquid/Gas ø mm Liquid line: φ 6.35(1/4")×5 / Gas line: φ 9.52 ( 3/8" ) × 5
Outdoor operating
temperature range
Cooling °C -15~46
Heating -15~24
Number of Connectable indoor units Min. 2 - Max. 5
Total indoor units capacity 16.0
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• In case of SRK71ZR + SRK71ZR, 2 Indoor units can be connectable. The total connecting capacity of indoor units should be between 100 ~ 160.