FDC280KXZME1

VRF Outdoor Unit

FDC280KXZME1

Micro Heat Pump VRF Outdoor Unit

Nominal cooling capacity of 28.0kW R410A

Nominal horse power10HP
Power source3 Phase 380-415V, 50Hz
Starting currentA5
Max CurrentA20
Nominal capacityCoolingkW28.0
Heating28.0
Electrical characteristics
Power Consumption
CoolingkW7.90
Heating6.53
Exterior dimensionsHxWxDmm1675x1080x480
Sound pressure levelCooling/HeatingdB(A)60/60
Net Weightkg221
RefrigerantType / GWPR410A / 2088
RefrigerantChargekg/TCO2Eq11.5 / 24.012
Refrigerant piping sizeLiquid linemm(in)ø9.52(3/8")
Refrigerant piping sizeGas linemm(in)ø22.22(7/8")
Capacity connection%50~150
Number of connectable indoor units24
SEER / SCOP (Outdoor unit)6.03 / 4.54
The data are measured under the following conditions(ISO-T1).
Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
[ ] : Pipe sizes applicable to European installations are shown in parentheses.