| Indoor unit | SRR60ZS-W | ||||
| Outdoor unit | SRC60ZSX-W3 | ||||
| Power source | 1Phase, 220 - 240, 50Hz | ||||
| Nominal cooling capacity (Min~Max) | kW | 5.6 (1.2 ~ 6.5) | |||
| Nominal heating capacity (Min~Max) | kW | 6.7 (1.0 ~ 8.6) | |||
| Power consumption | Cooling/Heating | kW | 1.70 / 1.89 | ||
| EER/COP | Cooling/Heating | 3.29 / 3.54 | |||
| Max. running current | A | 15 | |||
| Sound power level | Indoor | Cooling/Heating | dB(A) | 60 / 63 | |
| Outdoor | Cooling/Heating | 65 / 65 | |||
| Sound pressure level | Indoor | Cooling (Hi/Me/Lo/Ulo) | 44 / 38 / 35 / 30 | ||
| Heating (Hi/Me/Lo/Ulo) | 45 / 41 / 38 / 33 | ||||
| Outdoor | Cooling/Heating | 52 / 53 | |||
| Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 14.5 / 11.5 / 10.5 / 8.0 | |
| Heating (Hi/Me/Lo/Ulo) | 15.0 / 13.0 / 11.5 / 9.0 | ||||
| Outdoor | Cooling/Heating | 39.0 / 33.0 | |||
| Available external static pressure | Pa | Standard: 5*1 (Initial static pressure with air filler: 5Pa) | |||
| Exterior Dimensions | Indoor | Height x Width x Depth | mm | 200 x 950 x 500 | |
| Outdoor | 640 x 800(+71) x 290 | ||||
| Net weight | Indoor / Outdoor | kg | 24 / 45 | ||
| Refrigerant | Type/GWP | R32/675 | |||
| Refrigerant | Charge | kg/TCO2Eq | 1.30 / 0.878 | ||
| Refrigerant piping size | Liquid/Gas | mm (⌀ inch) | 6.35(1/4") / 12.7(1/2") | ||
| Refrigerant line (one way) length | m | Max. 30 | |||
| Vertical height differences | Outdoor is higher/lower | m | Max. 20 / Max.20 | ||
| Outdoor operating temperature range | Cooling | °C | -15~46 | ||
| Heating | -15~24 | ||||
| Bottom air inlet kit (option) | UT-BAT2EF | ||||
| SEER | 6.20 | ||||
| SCOP (Average climate) | 4.30 | ||||
| Pdesign (cooling/heating(@-10°C)) | kW | 5.00/4.50 | |||
| Annual Electricity Consumption (cooling/heating) | kWh/a | 270/1431 | |||
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.