SRR50ZS-W/SRC50ZSX-W3

5.0 (1.2 ~ 6.0) Ceiling Concealed Single Split RAC

SRR50ZS-W/SRC50ZSX-W3

Ceiling Concealed : 5.0 (1.2 ~ 6.0)

Indoor Unit - SRR50ZS-W / Outdoor Unit - SRC50ZSX-W3
Nominal cooling capacity of 5.0kW

R32
  • SRR50ZS-W
  • SRR50ZS-W

    Indoor Unit : SRR50ZS-W

    SRC50ZSX-W3

    Outdoor Unit : SRC50ZSX-W3

  • SRC50ZSX-W3
Indoor unitSRR50ZS-W
Outdoor unitSRC50ZSX-W3
Power source1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max)kW5.0 (1.2 ~ 6.0)
Nominal heating capacity (Min~Max)kW5.4 (1.0 ~ 8.2)
Power consumptionCooling/HeatingkW1.42 / 1.39
EER/COPCooling/Heating3.52 / 3.88
Max. running currentA15
Sound power
level
IndoorCooling/HeatingdB(A)59 / 61
OutdoorCooling/Heating63 / 62
Sound pressure
level
IndoorCooling (Hi/Me/Lo/Ulo)41 / 37 / 34 / 29
Heating (Hi/Me/Lo/Ulo)43 / 39 / 37 / 32
OutdoorCooling/Heating51 / 49
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min13.5 / 11.0 / 10.0 / 7.5
Heating (Hi/Me/Lo/Ulo)14.0 / 12.5 / 11.0 / 8.5
OutdoorCooling/Heating39.0 / 33.0
Available external static pressurePaStandard: 5*1 (Initial static pressure with air filler: 5Pa)
Exterior DimensionsIndoorHeight x Width x Depthmm200 x 950 x 500
Outdoor640 x 800(+71) x 290
Net weightIndoor / Outdoorkg24 / 45
RefrigerantType/GWPR32/675
RefrigerantChargekg/TCO2Eq1.30 / 0.878
Refrigerant piping sizeLiquid/Gasø inch6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) lengthmMax. 30
Vertical height differencesOutdoor is higher/lowermMax. 20 / Max.20
Outdoor operating
temperature range
Cooling°C-15~46
Heating-15~24
Bottom air inlet kit (option)UT-BAT2EF
SEER6.50
SCOP (Average climate)4.40
Pdesign (cooling/heating(@-10°C))kW5.00/4.50
Annual Electricity Consumption (cooling/heating)kWh/a270/1431
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.

We are currently experiencing technical issues with our Smart M Air App

For those of you who are still experiencing technical issues with our Smart M Air App, please update the app to the latest version via Google play (for Android) or Apple store (for iOS).