SRK71VNPWZR

7.1 ( 1.5 ~ 7.3 ) Wall Mounted Single Split PAC

SRK71VNPWZR

Wall Mounted : 7.1 ( 1.5 ~ 7.3 )

Indoor Unit - SRK71ZR-W / Outdoor Unit - FDC71VNP-W
Nominal cooling capacity of 7.1kW

R32
  • SRK71ZR-W
  • SRK71ZR-W

    Indoor Unit : SRK71ZR-W

    FDC71VNP-W

    Outdoor Unit : FDC71VNP-W

  • FDC71VNP-W
Indoor unit SRK71ZR-W
Outdoor unit FDC71VNP-W
Power source 1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 7.1 ( 1.5 ~ 7.3 )
Nominal heating capacity (Min~Max) kW 7.1 ( 1.1 ~ 7.3 )
Power consumption Cooling/Heating kW 2.36 / 1.88
EER/COP Cooling/Heating 3.01 / 3.78
Inrush current A 5
Max. running current A 15.8
Sound power
level*1
Indoor Cooling/Heating dB(A) 57 / 60
Outdoor Cooling/Heating 67 / 67
Sound pressure
level*1
Indoor Cooling (Hi/Me/Lo/Ulo) 44 / 41 / 37 / 25
Heating (Hi/Me/Lo/Ulo) 46 / 39 / 35 / 28
Outdoor Cooling/Heating 54 / 54
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 20.5 / 18.6 / 16.2 / 10.4
Heating (Hi/Me/Lo/Ulo) 25.0 / 19.8 / 17.3 / 13.3
Outdoor Cooling/Heating 42 / 42
Exterior Dimensions Indoor Height x Width x Depth mm Unit: 339 x 1,197 x 262
Outdoor 640 x 800(+71) x 290
Net weight Indoor / Outdoor kg 15.5 / 45
Refrigerant Type/GWP R32/675
Refrigerant Charge kg/TCO2Eq 1.3/0.878
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) length m Max.30
Vertical height differences Outdoor is higher/lower m Max.20 / Max.20
Outdoor operating
temperature range
Cooling*2 °C -15~46
Heating -20~20
Air filter quantity Polypropylene net x 2(washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 & Interface kit:SC-BIKN2-E
Energy Class (Cooling/Heating) A++/A+
SEER 6.75
SCOP (Average climate) 4.55
Pdesign (cooling/heating(@-10°C)) kW 7.10/5.70
Annual Electricity Consumption (cooling/heating) kWh/a 369/1756
Designated Heating Season Average
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.