SRK60ZSX-S / SRC60ZSX-S

6.1 (1.0~6.8) Wall Mounted Single Split RAC

SRK60ZSX-S / SRC60ZSX-S

Wall Mounted : 6.1 (1.0~6.8)

Indoor Unit - SRK60ZSX-S / Outdoor Unit - SRC60ZSX-S
Nominal cooling capacity of 6.0kW

R410A
  • SRK60ZSX-S
  • SRK60ZSX-S

    Indoor Unit : SRK60ZSX-S

    SRC60ZSX-S

    Outdoor Unit : SRC60ZSX-S

  • SRC60ZSX-S
Indoor unit SRK60ZSX-S
Outdoor unit SRC60ZSX-S
Power source 1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max) kW 6.1 (1.0~6.8)
Nominal heating capacity (Min~Max) kW 6.8 (0.6~8.7)
Power consumption Cooling/Heating kW 1.81 / 1.67
EER/COP Cooling/Heating 3.37 / 4.07
Max. running current A 15
Sound power
level
Indoor Cooling/Heating dB(A) 62 / 63
Outdoor Cooling/Heating 65 / 64
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 46 / 41 / 33 / 22
Heating (Hi/Me/Lo/Ulo) 46 / 42 / 34 / 23
Outdoor Cooling/Heating 52 / 52
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 16.3 / 13.4 / 8.9 / 5.4
Heating (Hi/Me/Lo/Ulo) 17.8 / 13.7 / 10.9 / 6.2
Outdoor Cooling/Heating 41.5 / 39.0
Exterior Dimensions Indoor Height x Width x Depth mm 305 x 920 x 220
Outdoor 640 x 800(+71) x 290
Net weight Indoor / Outdoor kg 13.0 / 43.0
Refrigerant Type/GWP R410A / 2088
Refrigerant Charge kg/TCO2Eq 1.50/3.132
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) length m Max.30
Vertical height differences Outdoor is higher/lower m Max.20 / Max.20
Outdoor operating
temperature range
Cooling °C -15~46
Heating -20~24
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) A++/A++
SEER 7.60
SCOP (Average climate) 4.70
Pdesign (cooling/heating(@-10°C)) kW 6.10/5.20
Annual Electricity Consumption (cooling/heating) kWh/a 282/1551
Designated Heating Season Average
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281