| Indoor unit | SRK50ZSX-WFT | ||||
| Outdoor unit | SRC50ZSX-W3 | ||||
| Power source | 1Phase, 220 - 240, 50Hz | ||||
| Nominal cooling capacity (Min~Max) | kW | 5.0 (1.0~6.2) | |||
| Nominal heating capacity (Min~Max) | kW | 6.0 (0.8~8.2) | |||
| Power consumption | Cooling/Heating | kW | 1.24 / 1.36 | ||
| EER/COP | Cooling/Heating | 4.03 / 4.41 | |||
| Max. running current | A | 15 | |||
| Sound power level | Indoor | Cooling/Heating | dB(A) | 59 / 62 | |
| Outdoor | Cooling/Heating | 63 / 61 | |||
| Sound pressure level | Indoor | Cooling (Hi/Me/Lo/Ulo) | 44 / 39 / 31 / 22 | ||
| Heating (Hi/Me/Lo/Ulo) | 47 / 41 / 33 / 23 | ||||
| Outdoor | Cooling/Heating | 51 / 49 | |||
| Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 14.3 / 12.4 / 7.8 / 5.4 | |
| Heating (Hi/Me/Lo/Ulo) | 17.3 / 14.3 / 9.8 / 6.2 | ||||
| Outdoor | Cooling/Heating | 39.0 / 33.0 | |||
| Exterior Dimensions | Indoor | Height x Width x Depth | mm | 305 x 920 x 220 | |
| Outdoor | 640 x 800(+71) x 290 | ||||
| Net weight | Indoor / Outdoor | kg | 13.0 / 45.0 | ||
| Refrigerant | Type/GWP | R32 / 675 | |||
| Refrigerant | Charge | kg/TCO2Eq | 1.30 / 0.878 | ||
| Refrigerant piping size | Liquid/Gas | mm (⌀ inch) | 6.35(1/4") / 12.7(1/2") | ||
| Refrigerant line (one way) length | m | Max.30 | |||
| Vertical height differences | Outdoor is higher/lower | m | Max.20 / Max.20 | ||
| Outdoor operating temperature range | Cooling | °C | -15~46 | ||
| Heating | -20~24 | ||||
| Clean filter | Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1 | ||||
| Energy Class (Cooling/Heating) | A++/A++ | ||||
| SEER | 8.30 | ||||
| SCOP (Average climate) | 4.70 | ||||
| Pdesign (cooling/heating(@-10°C)) | kW | 5.00/4.50 | |||
| Annual Electricity Consumption (cooling/heating) | kWh/a | 211/1341 | |||
| Designated Heating Season | Average | ||||
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.