| Indoor unit | SRK50ZSP-W1 | ||||
| Outdoor unit | SRC50ZSP-W1 | ||||
| Power source | 1 Phase, 220 - 240V, 50Hz | ||||
| Nominal cooling capacity (Min~Max) | kW | 5.0 (1.3~5.2) | |||
| Nominal heating capacity (Min~Max) | kW | 5.6 (1.2~5.8) | |||
| Power consumption | Cooling/Heating | kW | 1.740 / 1.660 | ||
| EER/COP | Cooling/Heating | 2.87 / 3.37 | |||
| Max. running current | A | 14.5 | |||
| Sound power level | Indoor | Cooling/Heating | dB(A) | 59 / 62 | |
| Outdoor | Cooling/Heating | 65 / 65 | |||
| Sound pressure level | Indoor | Cooling (Hi/Me/Lo/Ulo) | 46 / 37 / 22 | ||
| Heating (Hi/Me/Lo/Ulo) | 48 / 40 / 28 | ||||
| Outdoor | Cooling/Heating | 52 / 52 | |||
| Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 10.5 / 7.8 / 3.7 | |
| Heating (Hi/Me/Lo/Ulo) | 12.0 / 8.8 / 5.4 | ||||
| Outdoor | Cooling/Heating | 37.7 / 35.6 | |||
| Exterior Dimensions | Indoor | Height x Width x Depth | mm | 267 x 783 x 210 | |
| Outdoor | 595 x 780(+62) x 290 | ||||
| Net weight | Indoor / Outdoor | kg | 7.5 / 33.0 | ||
| Refrigerant | Type/GWP | R32 / 675 | |||
| Refrigerant | Charge | kg/TCO2Eq | 0.950 / 0.641 | ||
| Refrigerant piping size | Liquid/Gas | mm (⌀ inch) | 6.35 ( 1/4" ) / 12.7 ( 1/2” ) | ||
| Refrigerant line (one way) length | m | Max. 25 | |||
| Vertical height differences | Outdoor is higher/lower | m | Max. 15 / Max. 15 | ||
| Outdoor operating temperature range | Cooling | °C | -15~46 | ||
| Heating | -15~24 | ||||
| Clean filter | - | ||||
| Energy Class (Cooling/Heating) | A++/A+ | ||||
| SEER | 6.30 | ||||
| SCOP (Average climate) | 4.20 | ||||
| Pdesign (cooling/heating(@-10°C)) | kW | 5.00/3.80 | |||
| Annual Electricity Consumption (cooling/heating) | kWh/a | 278/1266 | |||
| Designated Heating Season | Average | ||||
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.