Indoor unit | SRK50ZSP-W | ||||
Outdoor unit | SRC50ZSP-W | ||||
Power source | 1 Phase, 220 - 240V, 50Hz | ||||
Nominal cooling capacity (Min~Max) | kW | 5.0 (1.3~5.2) | |||
Nominal heating capacity (Min~Max) | kW | 5.6 (1.2~5.8) | |||
Power consumption | Cooling/Heating | kW | 1.740 / 1.660 | ||
EER/COP | Cooling/Heating | 2.87 / 3.37 | |||
Max. running current | A | 14.5 | |||
Sound power level |
Indoor | Cooling/Heating | dB(A) | 59 / 63 | |
Outdoor | Cooling/Heating | 65 / 66 | |||
Sound pressure level |
Indoor | Cooling (Hi/Me/Lo/Ulo) | 46 / 39 / 24 / - | ||
Heating (Hi/Me/Lo/Ulo) | 48 / 41 / 30 / - | ||||
Outdoor | Cooling/Heating | 52 / 52 | |||
Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 9.9 / 7.2 / 3.8 / - | |
Heating (Hi/Me/Lo/Ulo) | 12.0 / 9.2 / 6.2 / - | ||||
Outdoor | Cooling/Heating | 37.7 / 35.6 | |||
Exterior Dimensions | Indoor | Height x Width x Depth | mm | 267 x 783 x 210 | |
Outdoor | 595 x 780(+62) x 290 | ||||
Net weight | Indoor / Outdoor | kg | 7.5 / 36.0 | ||
Refrigerant | Type/GWP | R32 / 675 | |||
Refrigerant | Charge | kg/TCO2Eq | 1.10 / 0.743 | ||
Refrigerant piping size | Liquid/Gas | ø mm | 6.35 ( 1/4" ) / 12.7 ( 1/2” ) | ||
Refrigerant line (one way) length | m | Max. 25 | |||
Vertical height differences | Outdoor is higher/lower | m | Max. 15 / Max. 15 | ||
Outdoor operating temperature range |
Cooling | °C | 15~46 | ||
Heating | -15~24 | ||||
Clean filter | - | ||||
Energy Class (Cooling/Heating) | A++/A+ | ||||
SEER | 6.20 | ||||
SCOP (Average climate) | 4.20 |
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281