SRK35ZSX-W / SRC35ZSX-W

3.5 (0.9~4.5) Wall Mounted Single Split RAC

SRK35ZSX-W / SRC35ZSX-W

Wall Mounted : 3.5 (0.9~4.5)

Indoor Unit - SRK35ZSX-W / Outdoor Unit - SRC35ZSX-W
Nominal cooling capacity of 3.5kW

R32
  • SRK35ZSX-W
  • SRK35ZSX-W

    Indoor Unit : SRK35ZSX-W

    SRC35ZSX-W

    Outdoor Unit : SRC35ZSX-W

  • SRC35ZSX-W
Indoor unit SRK35ZSX-W
Outdoor unit SRC35ZSX-W
Power source 1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max) kW 3.5 (0.9~4.5)
Nominal heating capacity (Min~Max) kW 4.3 (0.8~6.8)
Power consumption Cooling/Heating kW 0.74 / 0.90
EER/COP Cooling/Heating 4.73 / 4.78
Max. running current A 9
Sound power
level
Indoor Cooling/Heating dB(A) 58 / 58
Outdoor Cooling/Heating 61 / 62
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 43 / 35 / 26 / 19
Heating (Hi/Me/Lo/Ulo) 42 / 35 / 28 / 19
Outdoor Cooling/Heating 48 / 47
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 13.1 / 10.8 / 7.3 / 5.0
Heating (Hi/Me/Lo/Ulo) 13.9 / 11.8 / 8.6 / 5.4
Outdoor Cooling/Heating 36.0 / 31.0
Exterior Dimensions Indoor Height x Width x Depth mm 305 x 920 x 220
Outdoor 640 x 800(+71) x 290
Net weight Indoor / Outdoor kg 13.0 / 43.0
Refrigerant Type/GWP R32 / 675
Refrigerant Charge kg/TCO2Eq 1.20 / 0.810
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) length m Max.25
Vertical height differences Outdoor is higher/lower m Max.15 / Max.15
Outdoor operating
temperature range
Cooling °C -15~46
Heating -20~24
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) A+++/A+++
SEER 9.50
SCOP (Average climate) 5.10
Pdesign (cooling/heating(@-10°C)) kW 3.50/3.40
Annual Electricity Consumption (cooling/heating) kWh/a 129/934
Designated Heating Season Average
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281