SRK35ZSX-S / SRC35ZSX-S

3.5 (0.9~4.3) Wall Mounted Single Split RAC

SRK35ZSX-S / SRC35ZSX-S

Wall Mounted : 3.5 (0.9~4.3)

Indoor Unit - SRK35ZSX-S / Outdoor Unit - SRC35ZSX-S
Nominal cooling capacity of 3.5kW

R410A
  • SRK35ZSX-S
  • SRK35ZSX-S

    Indoor Unit : SRK35ZSX-S

    SRC35ZSX-S

    Outdoor Unit : SRC35ZSX-S

  • SRC35ZSX-S
Indoor unit SRK35ZSX-S
Outdoor unit SRC35ZSX-S
Power source 1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max) kW 3.5 (0.9~4.3)
Nominal heating capacity (Min~Max) kW 4.3 (0.8~6.6)
Power consumption Cooling/Heating kW 0.78 / 0.90
EER/COP Cooling/Heating 4.49 / 4.78
Max. running current A 9
Sound power
level
Indoor Cooling/Heating dB(A) 58 / 58
Outdoor Cooling/Heating 61 / 62
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 43 / 35 / 26 / 19
Heating (Hi/Me/Lo/Ulo) 41 / 35 / 28 / 19
Outdoor Cooling/Heating 48 / 47
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 13.1 / 10.8 / 7.3 / 5.0
Heating (Hi/Me/Lo/Ulo) 13.9 / 11.8 / 8.6 / 5.4
Outdoor Cooling/Heating 36.0 / 31.0
Exterior Dimensions Indoor Height x Width x Depth mm 305 x 920 x 220
Outdoor 640 x 800(+71) x 290
Net weight Indoor / Outdoor kg 13.0 / 43.0
Refrigerant Type/GWP R410A / 2088
Refrigerant Charge kg/TCO2Eq 1.45 / 3.028
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) length m Max.25
Vertical height differences Outdoor is higher/lower m Max.15 / Max.15
Outdoor operating
temperature range
Cooling °C -15~46
Heating -20~24
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) A+++/A+++
SEER 9.20
SCOP (Average climate) 5.10
Pdesign (cooling/heating(@-10°C)) kW 3.50/3.30
Annual Electricity Consumption (cooling/heating) kWh/a 134/906
Designated Heating Season Average
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281