SRK35ZSP-W / SRC35ZSP-W

3.2(0.9~3.7) Wall Mounted Single Split RAC

SRK35ZSP-W / SRC35ZSP-W

Wall Mounted : 3.2(0.9~3.7)

Indoor Unit - SRK35ZSP-W / Outdoor Unit - SRC35ZSP-W
Nominal cooling capacity of 3.5kW

R32
  • SRK35ZSP-W
  • SRK35ZSP-W

    Indoor Unit : SRK35ZSP-W

    SRC35ZSP-W

    Outdoor Unit : SRC35ZSP-W

  • SRC35ZSP-W
Indoor unitSRK35ZSP-W
Outdoor unitSRC35ZSP-W
Power source1 Phase, 220 - 240V, 50Hz
Nominal cooling capacity (Min~Max)kW3.2(0.9~3.7)
Nominal heating capacity (Min~Max)kW3.6(1.0~4.6)
Power consumptionCooling/HeatingkW0.910 / 0.930
EER/COPCooling/Heating3.52 / 3.87
Max. running currentA9
Sound power
level
IndoorCooling/HeatingdB(A)58 / 58
OutdoorCooling/Heating59 / 60
Sound pressure
level
IndoorCooling (Hi/Me/Lo/Ulo)45 / 36 / 23
Heating (Hi/Me/Lo/Ulo)44 / 36 / 28
OutdoorCooling/Heating48 / 48
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min9.5 / 6.8 / 4.2
Heating (Hi/Me/Lo/Ulo)9.6 / 7.4 / 5.5
OutdoorCooling/Heating22.8 / 22.0
Exterior DimensionsIndoorHeight x Width x Depthmm267 x 783 x 210
Outdoor540 x 645(+57) x 275
Net weightIndoor / Outdoorkg7.0 / 28.5
RefrigerantType/GWPR32 / 675
RefrigerantChargekg/TCO2Eq0.68 / 0.459
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) lengthmMax. 15
Vertical height differencesOutdoor is higher/lowermMax. 10 / Max. 10
Outdoor operating
temperature range
Cooling°C-15~46
Heating-15~24
Clean filter-
Energy Class (Cooling/Heating)A++/A+
SEER7.30
SCOP (Average climate)4.40
Pdesign (cooling/heating(@-10°C))kW3.20/3.00
Annual Electricity Consumption (cooling/heating)kWh/a155/955
Designated Heating SeasonAverage
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281