SRK25ZT-WFB / SRC25ZT-W(B)

2.5(0.9~3.3) Wall Mounted Single Split RAC

SRK25ZT-WFB / SRC25ZT-W(B)

Wall Mounted : 2.5(0.9~3.3)

Indoor Unit - SRK25ZT-WFB / Outdoor Unit - SRC25ZT-W(B)
Nominal cooling capacity of 2.5kW

R32
  • SRK25ZT-WFB
  • SRK25ZT-WFB

    Indoor Unit : SRK25ZT-WFB

     SRC25ZT-W(B)

    Outdoor Unit : SRC25ZT-W(B)

  •  SRC25ZT-W(B)
Indoor unitSRK25ZT-WFB
Outdoor unit SRC25ZT-W(B)
Power source1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max)kW2.5(0.9~3.3)
Nominal heating capacity (Min~Max)kW3.2(0.9~4.7)
Power consumptionCooling/HeatingkW0.57 / 0.70
EER/COPCooling/Heating4.39 / 4.57
Max. running currentA9
Sound power
level
IndoorCooling/HeatingdB(A)50 / 52
OutdoorCooling/Heating56 / 58
Sound pressure
level
IndoorCooling (Hi/Me/Lo/Ulo)35 / 28 / 23 / 19
Heating (Hi/Me/Lo/Ulo)38 / 30 / 24 / 19
OutdoorCooling/Heating45 / 46
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min10.0 / 8.3 / 6.0 / 5.0
Heating (Hi/Me/Lo/Ulo)10.6 / 9.0 / 6.5 / 5.3
OutdoorCooling/Heating23.3 / 25.3
Exterior DimensionsIndoorHeight x Width x Depthmm290 x 870 x 230
Outdoor540 × 780 (+62) × 290
Net weightIndoor / Outdoorkg10.5 / 33.0
RefrigerantType/GWPR32 / 675
RefrigerantChargekg/TCO2Eq0.76 / 0.513
Refrigerant piping sizeLiquid/Gasmm (⌀ inch)6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) lengthmMax. 20
Vertical height differencesOutdoor is higher/lowermMax. 15 / Max. 15
Outdoor operating
temperature range
Cooling°C-15~50
Heating-20~24
Clean filterAllergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating)A+++/A+++
SEER9.5
SCOP (Average climate)5.1
Pdesign (cooling/heating(@-10°C))kW2.50/2.70
Annual Electricity Consumption (cooling/heating)kWh/a93/741
Designated Heating SeasonAverage
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281