| Indoor unit | SRK25ZSP-W1 | ||||
| Outdoor unit | SRC25ZSP-W1 | ||||
| Power source | 1Phase, 220 - 240, 50Hz | ||||
| Nominal cooling capacity (Min~Max) | kW | 2.5(0.8~3.2) | |||
| Nominal heating capacity (Min~Max) | kW | 2.8(0.8~4.1) | |||
| Power consumption | Cooling/Heating | kW | 0.710 / 0.690 | ||
| EER/COP | Cooling/Heating | 3.52/4.05 | |||
| Max. running current | A | 9 | |||
| Sound power level | Indoor | Cooling/Heating | dB(A) | 57 / 56 | |
| Outdoor | Cooling/Heating | 57 / 57 | |||
| Sound pressure level | Indoor | Cooling (Hi/Me/Lo/Ulo) | 44 / 33 / 21 | ||
| Heating (Hi/Me/Lo/Ulo) | 42 / 33 / 25 | ||||
| Outdoor | Cooling/Heating | 47 / 45 | |||
| Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 10.0 / 7.6 / 4.3 | |
| Heating (Hi/Me/Lo/Ulo) | 9.6 / 7.6 / 5.3 | ||||
| Outdoor | Cooling/Heating | 21.9 / 21.9 | |||
| Exterior Dimensions | Indoor | Height x Width x Depth | mm | 267 x 783 x 210 | |
| Outdoor | 540 x 645(+57) x 275 | ||||
| Net weight | Indoor / Outdoor | kg | 7.0 / 22.0 | ||
| Refrigerant | Type/GWP | R32 / 675 | |||
| Refrigerant | Charge | kg/TCO2Eq | 0.480 / 0.324 | ||
| Refrigerant piping size | Liquid/Gas | mm (⌀ inch) | 6.35(1/4") / 9.52(3/8") | ||
| Refrigerant line (one way) length | m | Max. 15 | |||
| Vertical height differences | Outdoor is higher/lower | m | Max. 15 / Max. 15 | ||
| Outdoor operating temperature range | Cooling | °C | -15~46 | ||
| Heating | -15~24 | ||||
| Clean filter | - | ||||
| Energy Class (Cooling/Heating) | A++/A+ | ||||
| SEER | 6.90 | ||||
| SCOP (Average climate) | 4.10 | ||||
| Pdesign (cooling/heating(@-10°C)) | kW | 2.50/2.70 | |||
| Annual Electricity Consumption (cooling/heating) | kWh/a | 127/923 | |||
| Designated Heating Season | Average | ||||
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.