SRK25ZSP-S / SRC25ZSP-S

2.5(0.9~2.8) Wall Mounted Single Split RAC

SRK25ZSP-S / SRC25ZSP-S

Wall Mounted : 2.5(0.9~2.8)

Indoor Unit - SRK25ZSP-S / Outdoor Unit - SRC25ZSP-S
Nominal cooling capacity of 2.5kW

R410A
  • SRK25ZSP-S
  • SRK25ZSP-S

    Indoor Unit : SRK25ZSP-S

    SRC25ZSP-S

    Outdoor Unit : SRC25ZSP-S

  • SRC25ZSP-S
Indoor unitSRK25ZSP-S
Outdoor unitSRC25ZSP-S
Power source1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max)kW2.5(0.9~2.8)
Nominal heating capacity (Min~Max)kW2.8(0.8~3.9)
Power consumptionCooling/HeatingkW0.78 / 0.755
EER/COPCooling/Heating3.21/3.71
Max. running currentA9
Sound power
level
IndoorCooling/HeatingdB(A)58 / 57
OutdoorCooling/Heating58 / 59
Sound pressure
level
IndoorCooling (Hi/Me/Lo/Ulo)45 / 34 / 23
Heating (Hi/Me/Lo/Ulo)43 / 34 / 26
OutdoorCooling/Heating47 / 45
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min10.0 / 7.3 / 4.2
Heating (Hi/Me/Lo/Ulo)9.5 / 7.3 / 5.2
OutdoorCooling/Heating26.0 / 19.7
Exterior DimensionsIndoorHeight x Width x Depthmm267 x 783 x 210
Outdoor540 x 645(+57) x 275
Net weightIndoor / Outdoorkg7.0 / 25.0
RefrigerantType/GWPR410A / 2088
RefrigerantChargekg/TCO2Eq0.655 / 1.368
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) lengthmMax. 15
Vertical height differencesOutdoor is higher/lowermMax. 10 / Max. 10
Outdoor operating
temperature range
Cooling°C-15~46
Heating-15~24
Clean filter-
Energy Class (Cooling/Heating)A/A
SEER5.50
SCOP (Average climate)3.80
Pdesign (cooling/heating(@-10°C))kW2.50/2.80
Annual Electricity Consumption (cooling/heating)kWh/a160/1033
Designated Heating SeasonAverage
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281