SRK25ZS-ST / SRC25ZS-S

2.5(1.0~3.0) Wall Mounted Single Split RAC

SRK25ZS-ST / SRC25ZS-S

Wall Mounted : 2.5(1.0~3.0)

Indoor Unit - SRK25ZS-ST / Outdoor Unit - SRC25ZS-S
Nominal cooling capacity of 2.5kW

R410A
  • SRK25ZS-ST
  • SRK25ZS-ST

    Indoor Unit : SRK25ZS-ST

    SRC25ZS-S

    Outdoor Unit : SRC25ZS-S

  • SRC25ZS-S
Indoor unit SRK25ZS-ST
Outdoor unit SRC25ZS-S
Power source 1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max) kW 2.5(1.0~3.0)
Nominal heating capacity (Min~Max) kW 3.2(0.9~4.4)
Power consumption Cooling/Heating kW 0.62 / 0.80
EER/COP Cooling/Heating 4.03 / 4.00
Max. running current A 9
Sound power
level
Indoor Cooling/Heating dB(A) 52 / 55
Outdoor Cooling/Heating 58 / 58
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 36 / 28 / 23 / 19
Heating (Hi/Me/Lo/Ulo) 39 / 30 / 24 / 19
Outdoor Cooling/Heating 46 / 46
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 9.9 / 8.0 / 5.9 / 5.0
Heating (Hi/Me/Lo/Ulo) 11.3 / 8.7 / 6.7 / 5.9
Outdoor Cooling/Heating 27.4 / 23.6
Exterior Dimensions Indoor Height x Width x Depth mm 290 x 870 x 230
Outdoor 540 x 780(+62) x 290
Net weight Indoor / Outdoor kg 9.5 / 31.5
Refrigerant Type/GWP R410A / 2088
Refrigerant Charge kg/TCO2Eq 0.75 / 1.566
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) length m Max. 20
Vertical height differences Outdoor is higher/lower m Max. 10 / Max. 10
Outdoor operating
temperature range
Cooling °C -15~46
Heating -15~24
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) A++/A++
SEER 7.80
SCOP (Average climate) 4.60
Pdesign (cooling/heating(@-10°C)) kW 2.50/2.50
Annual Electricity Consumption (cooling/heating) kWh/a 113/762
Designated Heating Season Average
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281