SRK20ZTX-WA / SRC20ZTX-WA

2.0 (0.9~3.5) Wall Mounted Single Split RAC

SRK20ZTX-WA / SRC20ZTX-WA

Wall Mounted : 2.0 (0.9~3.5)

Indoor Unit - SRK20ZTX-WA / Outdoor Unit - SRC20ZTX-WA
Nominal cooling capacity of 2.0kW

  • Nordic Model
  • Drain pan heater equipped
  • -25°C Heating
R32
  • SRK20ZTX-WA
  • SRK20ZTX-WA

    Indoor Unit : SRK20ZTX-WA

    SRC20ZTX-WA

    Outdoor Unit : SRC20ZTX-WA

  • SRC20ZTX-WA
Indoor unitSRK20ZTX-WA
Outdoor unitSRC20ZTX-WA
Power source1 Phase, 220 - 240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW2.0 (0.9~3.5)
Nominal heating capacity (Min~Max)kW2.7 (0.9~7.6)
Power consumptionCooling/HeatingkW0.32 / 0.47
EER/COPCooling/Heating6.25 / 5.74
Max. running currentA14.5
Sound power
level
IndoorCooling/HeatingdB(A)52 / 53
OutdoorCooling/Heating55 / 57
Sound pressure
level
IndoorCooling (Hi/Me/Lo/Ulo)38 / 31 / 24 / 19
Heating (Hi/Me/Lo/Ulo)40 / 33 / 25 / 19
OutdoorCooling/Heating43 / 45
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min10.7 / 8.6 / 5.8 / 4.8
Heating (Hi/Me/Lo/Ulo)14.2 / 10.4 / 7.2 / 5.6
OutdoorCooling/Heating31.0 / 31.0
Exterior DimensionsIndoorHeight x Width x Depthmm305 × 920 × 220
Outdoor640 x 800(+71) x 290
Net weightIndoor / Outdoorkg13.0 / 45.0
RefrigerantType/GWPR32 / 675
RefrigerantChargekg/TCO2Eq1.25
Refrigerant piping sizeLiquid/Gasmm (⌀ inch)6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) lengthmMax.25
Vertical height differencesOutdoor is higher/lowermMax.15 / Max.15
Outdoor operating
temperature range
Cooling°C-15~46 ̊C
Heating-25~24 ̊C
Clean filterAllergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating)A+++/A+++
SEER9.60
SCOP (Average climate)5.20
Pdesign (cooling/heating(@-10°C))kW2.00/2.80
Annual Electricity Consumption (cooling/heating)kWh/a73/755
Designated Heating SeasonAverage
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.