SRK20ZTL-W / SRC20ZTL-W

2.0 ( 0.7 ~ 2.8 ) Wall Mounted Single Split RAC

SRK20ZTL-W / SRC20ZTL-W

Wall Mounted : 2.0 ( 0.7 ~ 2.8 )

Indoor Unit - SRK20ZTL-W / Outdoor Unit - SRC20ZTL-W
Nominal cooling capacity of 2.0kW

R32
  • SRK20ZTL-W
  • SRK20ZTL-W

    Indoor Unit : SRK20ZTL-W

    SRC20ZTL-W

    Outdoor Unit : SRC20ZTL-W

  • SRC20ZTL-W
Indoor unitSRK20ZTL-W
Outdoor unitSRC20ZTL-W
Power source1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max)kW2.0 ( 0.7 ~ 2.8 )
Nominal heating capacity (Min~Max)kW2.7 ( 0.9 ~ 4.2 )
Power consumptionCooling/HeatingkW0.51 / 0.64
EER/COPCooling/Heating3.92 / 4.22
Max. running currentA9
Sound power
level
IndoorCooling/HeatingdB(A)52 / 54
OutdoorCooling/Heating57 / 57
Sound pressure
level
IndoorCooling (Hi/Me/Lo/Ulo)37 / 31 / 23 / 19
Heating (Hi/Me/Lo/Ulo)39 / 34 / 25 / 19
OutdoorCooling/Heating45 / 46
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min9.9 / 7.8 / 4.9 / 3.8
Heating (Hi/Me/Lo/Ulo)10.4 / 9.1 / 6.2 / 4.4
OutdoorCooling/Heating23.7 / 20.8
Exterior DimensionsIndoorHeight x Width x Depthmm294 x 798 x 210
Outdoor540 x 645 (+57) x 275
Net weightIndoor / Outdoorkg8.5 / 22.0
RefrigerantType/GWPR32 / 675
RefrigerantChargekg/TCO2Eq0.43 / 0.29
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) lengthmMax.20
Vertical height differencesOutdoor is higher/lowermMax.15 / Max.15
Outdoor operating
temperature range
Cooling°C-15~46
Heating-20~24
Clean filterAllergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating)A++/A+
SEER6.70
SCOP (Average climate)4.40
Pdesign (cooling/heating(@-10°C))kW2.00/2.40
Annual Electricity Consumption (cooling/heating)kWh/a105/764
Designated Heating SeasonAverage
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281