SRK20ZSX-S / SRC20ZSX-S

2.0 (0.9~3.2) Wall Mounted Single Split RAC

SRK20ZSX-S / SRC20ZSX-S

Wall Mounted : 2.0 (0.9~3.2)

Indoor Unit - SRK20ZSX-S / Outdoor Unit - SRC20ZSX-S
Nominal cooling capacity of 2.0kW

R410A
  • SRK20ZSX-S
  • SRK20ZSX-S

    Indoor Unit : SRK20ZSX-S

    SRC20ZSX-S

    Outdoor Unit : SRC20ZSX-S

  • SRC20ZSX-S
Indoor unit SRK20ZSX-S
Outdoor unit SRC20ZSX-S
Power source 1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max) kW 2.0 (0.9~3.2)
Nominal heating capacity (Min~Max) kW 2.7 (0.8~5.3)
Power consumption Cooling/Heating kW 0.32 / 0.47
EER/COP Cooling/Heating 6.25 / 5.74
Max. running current A 9
Sound power
level
Indoor Cooling/Heating dB(A) 53 / 53
Outdoor Cooling/Heating 56 / 58
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 38 / 31 / 24 / 19
Heating (Hi/Me/Lo/Ulo) 38 / 32 / 25 / 19
Outdoor Cooling/Heating 43 / 44
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 11.3 / 9.1 / 6.0 / 5.0
Heating (Hi/Me/Lo/Ulo) 12.2 / 10.3 / 7.2 / 5.4
Outdoor Cooling/Heating 31.0 / 31.0
Exterior Dimensions Indoor Height x Width x Depth mm 305 x 920 x 220
Outdoor 640 x 800(+71) x 290
Net weight Indoor / Outdoor kg 13.0 / 43.0
Refrigerant Type/GWP R410A / 2088
Refrigerant Charge kg/TCO2Eq 1.45 / 3.028
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 9.52(3/8")
Refrigerant line (one way) length m Max.25
Vertical height differences Outdoor is higher/lower m Max.15 / Max.15
Outdoor operating
temperature range
Cooling °C -15~46
Heating -20~24
Clean filter Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) A+++/A+++
SEER 9.50
SCOP (Average climate) 5.20
Pdesign (cooling/heating(@-10°C)) kW 2.00/2.70
Annual Electricity Consumption (cooling/heating) kWh/a 74/728
Designated Heating Season Average
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281