SRK100VSAZR

10.0 ( 4.0 ~ 11.2 ) Wall Mounted Single Split PAC

SRK100VSAZR

Wall Mounted : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - SRK100ZR-S / Outdoor Unit - FDC100VSA
Nominal cooling capacity of 10.0kW

R410A
  • SRK100ZR-S
  • SRK100ZR-S

    Indoor Unit : SRK100ZR-S

    FDC100VSA

    Outdoor Unit : FDC100VSA

  • FDC100VSA
Indoor unit SRK100ZR-S
Outdoor unit FDC100VSA
Power source 3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min~Max) kW 10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min~Max) kW 11.2 ( 4.0 ~ 12.5 )
Power consumption Cooling/Heating kW 3.19 / 2.78
EER/COP Cooling/Heating 3.13 / 4.03
Inrush current A 5
Max. running current A 15
Sound power
level*1
Indoor Cooling/Heating dB(A) 63 / 63
Outdoor Cooling/Heating 70 / 70
Sound pressure
level*1
Indoor Cooling (Hi/Me/Lo/Ulo) 48 / 45 / 40 / 27
Heating (Hi/Me/Lo/Ulo) 48 / 43 / 38 / 30
Outdoor Cooling/Heating 54 / 56
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 24.5 / 21.3 / 17.6/ 10.4
Heating (Hi/Me/Lo/Ulo) 27.5 / 23.2 / 19.1/ 13.6
Outdoor Cooling/Heating 75 / 73
Exterior Dimensions Indoor Height x Width x Depth mm 339 / 1,197 / 262
Outdoor 845 / 970 / 370
Net weight Indoor / Outdoor kg 16.5 / 82
Refrigerant Type/GWP R410A/2088
Refrigerant Charge kg/TCO2Eq 3.8/7.934
Refrigerant piping size Liquid/Gas ø mm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max.50
Vertical height differences Outdoor is higher/lower m Max.50 / Max.15
Outdoor operating
temperature range
Cooling*2 °C -15~50
Heating -20~20
Air filter quantity Polypropylene net x2 (Washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 & Interface kit:SC-BIKN2-E
Energy Class (Cooling/Heating) A++/A+
SEER 6.26
SCOP (Average climate) 4.33
Pdesign (cooling/heating(@-10°C)) kW 10.0/8.5
Annual Electricity Consumption (cooling/heating) kWh/a 560/2750
Designated Heating Season Average
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.