×

SRK100VNAWZR

10.0 ( 4.0 ~ 11.2 ) Wall Mounted Single Split PAC

SRK100VNAWZR

Wall Mounted : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - SRK100ZR-W / Outdoor Unit - FDC100VNA-W
Nominal cooling capacity of 10.0kW

R32
  • SRK100ZR-W
  • SRK100ZR-W

    Indoor Unit : SRK100ZR-W

    FDC100VNA-W

    Outdoor Unit : FDC100VNA-W

  • FDC100VNA-W
Indoor unitSRK100ZR-W
Outdoor unitFDC100VNA-W
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min~Max)kW11.2 ( 4.0 ~ 12.5 )
Power consumptionCooling/HeatingkW3.19 / 3.04
EER/COPCooling/Heating3.13 / 3.68
Inrush currentA5
Max. running currentA24
Sound power
level*1
IndoorCooling/HeatingdB(A)63 / 63
OutdoorCooling/Heating69 / 70
Sound pressure
level*1
IndoorCooling (Hi/Me/Lo/Ulo)48 / 45 / 40 / 27
Heating (Hi/Me/Lo/Ulo)48 / 43 / 38 / 30
OutdoorCooling/Heating54 / 55
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min24.5 / 21.3 / 17.6/ 10.4
Heating (Hi/Me/Lo/Ulo)27.5 / 23.2 / 19.1/ 13.6
OutdoorCooling/Heating75 / 73
Exterior DimensionsIndoorHeight x Width x DepthmmUnit: 339 x 1,197 x 262
Outdoor845 x 970 x 370
Net weightIndoor / Outdoorkg16.5 / 77
RefrigerantType/GWPR32/675
RefrigerantChargekg/TCO2Eq3.3/2.228
Refrigerant piping sizeLiquid/Gasø mm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.50
Vertical height differencesOutdoor is higher/lowermMax.50 / Max.15
Outdoor operating
temperature range
Cooling*2°C-15~50
Heating-20~20
Air filter quantityPolypropylene net x 2(washable)
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 & Interface kit:SC-BIKN2-E
Energy Class (Cooling/Heating)A++/A+
SEER6.13
SCOP (Average climate)4.33
Pdesign (cooling/heating(@-10°C))kW10.0/8.5
Annual Electricity Consumption (cooling/heating)kWh/a571/2746
Designated Heating SeasonAverage
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.