| Indoor unit | SRF50ZSX-W | ||||
| Outdoor unit | SRC50ZSX-W3 | ||||
| Power source | 1 Phase, 220 - 240V, 50Hz / 220V, 60Hz | ||||
| Nominal cooling capacity (Min~Max) | kW | 5.0 ( 1.1 (Min.) - 5.6 (Max.)) | |||
| Nominal heating capacity (Min~Max) | kW | 6.0 ( 0.8 (Min.) - 7.4 (Max.)) | |||
| Power consumption | Cooling/Heating | kW | 1.32 ( 0.19 - 1.90 ) / 1.58 ( 0.19 - 2.34 ) | ||
| EER/COP | Cooling/Heating | 3.79 / 3.80 | |||
| Max. running current | A | 15 | |||
| Sound power level | Indoor | Cooling/Heating | dB(A) | 58 / 58 | |
| Outdoor | Cooling/Heating | 63 / 62 | |||
| Sound pressure level | Indoor | Cooling (Hi/Me/Lo/Ulo) | 46 / 38 / 33 / 28 | ||
| Heating (Hi/Me/Lo/Ulo) | 46 / 41 / 38 / 32 | ||||
| Outdoor | Cooling/Heating | 51 / 51 | |||
| Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 11.5 / 9.6 / 7.4 / 6.6 | |
| Heating (Hi/Me/Lo/Ulo) | 12.0 / 10.0 / 9.4 / 7.6 | ||||
| Outdoor | Cooling/Heating | 39.0 / 33.0 | |||
| Exterior Dimensions | Indoor | Height x Width x Depth | mm | 600 x 860 x 238 | |
| Outdoor | 640 x 800 (+71) x 290 | ||||
| Net weight | Indoor / Outdoor | kg | 19.0 / 45.0 | ||
| Refrigerant | Type/GWP | R32/675 | |||
| Refrigerant | Charge | kg/TCO2Eq | 1.30 / 0.878 | ||
| Refrigerant piping size | Liquid/Gas | mm (⌀ inch) | 6.35 (1/4") / 12.7 (1/2") | ||
| Refrigerant line (one way) length | m | Max. 30 [15] | |||
| Vertical height differences | Outdoor is higher/lower | m | Max. 20 / Max. 20 | ||
| Outdoor operating temperature range | Cooling | °C | -15~46 | ||
| Heating | -15~24 | ||||
| Clean filter | Allergen Clean Filter x 1 Photocatalytic Washable Deodorising Filter x 1 | ||||
| Energy Class (Cooling/Heating) | A++/A++ | ||||
| SEER | 7.50 | ||||
| SCOP (Average climate) | 4.60 | ||||
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.