SRF50ZSX-W / SRC50ZSX-W2

5.0 ( 1.1 (Min.) - 5.6 (Max.)) Floor Standing Single Split RAC

SRF50ZSX-W / SRC50ZSX-W2

Floor Standing : 5.0 ( 1.1 (Min.) - 5.6 (Max.))

Indoor Unit - SRF50ZSX-W / Outdoor Unit - RC50ZSX-W2
Nominal cooling capacity of 5.0kW

R32
  • SRF50ZSX-W
  • SRF50ZSX-W

    Indoor Unit : SRF50ZSX-W

    RC50ZSX-W2

    Outdoor Unit : RC50ZSX-W2

  • RC50ZSX-W2
Indoor unit SRF50ZSX-W
Outdoor unit RC50ZSX-W2
Power source 1 Phase, 220 - 240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 5.0 ( 1.1 (Min.) - 5.6 (Max.))
Nominal heating capacity (Min~Max) kW 6.0 ( 0.8 (Min.) - 7.4 (Max.))
Power consumption Cooling/Heating kW 1.32 ( 0.19 - 1.90 ) / 1.58 ( 0.19 - 2.34 )
EER/COP Cooling/Heating 3.79 / 3.80
Max. running current A 15
Sound power
level
Indoor Cooling/Heating dB(A) 58 / 58
Outdoor Cooling/Heating 63 / 62
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 46 / 38 / 33 / 28
Heating (Hi/Me/Lo/Ulo) 46 / 41 / 38 / 32
Outdoor Cooling/Heating 51 / 51
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 11.5 / 9.6 / 7.4 / 6.6
Heating (Hi/Me/Lo/Ulo) 12.0 / 10.0 / 9.4 / 7.6
Outdoor Cooling/Heating 39.0 / 33.0
Exterior Dimensions Indoor Height x Width x Depth mm 600 x 860 x 238
Outdoor 640 x 800 (+71) x 290
Net weight Indoor / Outdoor kg 19.0 / 45.0
Refrigerant Type/GWP R32/675
Refrigerant Charge kg/TCO2Eq 1.30 / 0.878
Refrigerant piping size Liquid/Gas ø mm 6.35 (1/4") / 12.7 (1/2")
Refrigerant line (one way) length m Max. 30 [15]
Vertical height differences Outdoor is higher/lower m Max. 20 / Max. 20
Outdoor operating
temperature range
Cooling °C -20~24
Heating
Clean filter Allergen Clean Filter x 1 Photocatalytic Washable Deodorising Filter x 1
Energy Class (Cooling/Heating) A++/A++
SEER 7.50
SCOP (Average climate) 4.60
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281