SRF25ZS-W / SRC25ZS-W2

2.5 (0.9 ~ 3.1) Floor Standing Single Split RAC

SRF25ZS-W / SRC25ZS-W2

Floor Standing : 2.5 (0.9 ~ 3.1)

Indoor Unit - SRK25ZS-W / Outdoor Unit - SRC25ZS-W2
Nominal cooling capacity of 2.5kW

R32
  • SRK25ZS-W
  • SRK25ZS-W

    Indoor Unit : SRK25ZS-W

    SRC25ZS-W2

    Outdoor Unit : SRC25ZS-W2

  • SRC25ZS-W2
Indoor unit SRK25ZS-W
Outdoor unit SRC25ZS-W2
Power source 1 Phase, 220 - 240V, 50HZ
Nominal cooling capacity (Min~Max) kW 2.5 (0.9 ~ 3.1)
Nominal heating capacity (Min~Max) kW 2.9 (0.8 ~ 3.7)
Power consumption Cooling/Heating kW 0.59 / 0.66
EER/COP Cooling/Heating 4.24 / 4.39
Max. running current A 9
Sound power
level
Indoor Cooling/Heating dB(A) 50 / 51
Outdoor Cooling/Heating 59 / 60
Sound pressure
level
Indoor Cooling (Hi/Me/Lo/Ulo) 38 / 32 / 29 / 25
Heating (Hi/Me/Lo/Ulo) 39 / 35 / 33 / 29
Outdoor Cooling/Heating 45 / 47
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 9.0 / 7.6 / 6.7 / 5.8
Heating (Hi/Me/Lo/Ulo) 10.5 / 8.2 / 7.7 / 6.6
Outdoor Cooling/Heating 27.4 / 27.4
Exterior Dimensions Indoor Height x Width x Depth mm 600 x 860 x 238
Outdoor 540 x 780(+62) x 290
Net weight Indoor / Outdoor kg 18.0 / 31.0
Refrigerant Type/GWP R32/675
Refrigerant Charge kg/TCO2Eq 0.62 / 0.419
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 9.52 (3/8")
Refrigerant line (one way) length m Max.20 [10]
Vertical height differences Outdoor is higher/lower m Max. 10 / Max.10
Outdoor operating
temperature range
Cooling °C -15~46
Heating -15 ~ 24
Clean filter Allergen Clean Filter x 1 Photocatalytic Washable Deodorising Filter x 1
Energy Class (Cooling/Heating) A++/A+
SEER 7.40
SCOP (Average climate) 4.00
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*SEER/SCOP are based on EN14825:2016 and Commission regulation (EU) No.2016/2281