FDUM125VSAWVH

12.5 ( 5.0 ~ 14.0 ) Low Static Pressure Duct Connected Single Split PAC

FDUM125VSAWVH

Low Static Pressure Duct Connected : 12.5 ( 5.0 ~ 14.0 )

Indoor Unit - FDUM125VH / Outdoor Unit - FDC125VSA-W
Nominal cooling capacity of 12.5kW

R32
  • FDUM125VH
  • FDUM125VH

    Indoor Unit : FDUM125VH

    FDC125VSA-W

    Outdoor Unit : FDC125VSA-W

  • FDC125VSA-W
Indoor unit FDUM125VH
Outdoor unit FDC125VSA-W
Power source 3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min~Max) kW 12.5 ( 5.0 ~ 14.0 )
Nominal heating capacity (Min~Max) kW 14.0 ( 4.0 ~ 16.0 )
Power consumption Cooling/Heating kW 4.36 / 3.69
EER/COP Cooling/Heating 2.87 / 3.79
Inrush current A 5
Max. running current A 17
Sound power
level*1
Indoor *3 Cooling/Heating dB(A) 67 / 67
Outdoor Cooling/Heating 71 / 71
Sound pressure
level*1
Indoor *3 Cooling (Hi/Me/Lo/Ulo) 45 / 40 / 34 / 29
Heating (Hi/Me/Lo/Ulo) 45 / 40 / 34 / 29
Outdoor Cooling/Heating 54 / 56
Air flow Indoor *3 Cooling (Hi/Me/Lo/Ulo) m3/min 39 / 32 / 26 / 20
Heating (Hi/Me/Lo/Ulo) 39 / 32 / 26 / 20
Outdoor Cooling/Heating 75 / 73
Available external static pressure Pa Standard:60 Max:100
Exterior Dimensions Indoor Height x Width x Depth mm 280 x 1,370 x 740
Outdoor 845 x 970 x 370
Net weight Indoor / Outdoor kg 54 / 78
Refrigerant Type/GWP R32/675
Refrigerant piping size Liquid/Gas ø mm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max.50
Vertical height differences Outdoor is higher/lower m Max.50 / Max.15
Outdoor operating
temperature range
Cooling*2 °C -15~50
Heating -20~20
Air filter quantity (Option) Filter kit : UM-FL3EF
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
SEER 5.57
SCOP (Average climate) 4.13
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  4. : The values are for one indoor unit operation. (Multi system only)