FDUM125VSAWPVH

12.5 ( 5.0 ~ 14.0 ) Low Static Pressure Duct Connected Multi Split PAC

FDUM125VSAWPVH

Low Static Pressure Duct Connected : 12.5 ( 5.0 ~ 14.0 )

Indoor Unit - FDUM60VH x 2 / Outdoor Unit - FDC125VSA-W
Nominal cooling capacity of 12.5kW

R32
  • FDUM60VH x 2
  • FDUM60VH x 2

    Indoor Unit : FDUM60VH x 2

    FDC125VSA-W

    Outdoor Unit : FDC125VSA-W

  • FDC125VSA-W
Indoor unit FDUM60VH x 2
Outdoor unit FDC125VSA-W
Power source 3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min-Max) kW 12.5 ( 5.0 ~ 14.0 )
Nominal heating capacity (Min-Max) kW 14.0 ( 4.0 ~ 16.0 )
Power Consumption Cooling/Heating kW 4.53 / 3.52
EER/COP Cooling/Heating kW 2.76 / 3.98
Inrush current A 5
Max. current A 17
Sound power level*1 Indoor*3 Cooling/Heating dB(A) 60 / 60
Outdoor Cooling/Heating 71 / 71
Sound pressure
level*1
Indoor*3 Cooling (P-Hi/Hi/Me/Lo) 36 / 31 / 28 / 25
Heating (P-Hi/Hi/Me/Lo) 36 / 31 / 28 / 25
Outdoor Cooling/Heating 54 / 56
Air flow Indoor*3 Cooling (P-Hi/Hi/Me/Lo) m3/min 20 / 15 / 13 / 10
Heating (P-Hi/Hi/Me/Lo) 20 / 15 / 13 / 10
Outdoor Cooling/Heating 75 / 73
External static pressure Pa Standard:35 Max:100
Exterior
dimensions
Indoor HeightxWidthxDepth mm 280 x 950 x 635
Outdoor mm 845 x 970 x 370
Net weight Indoor/Outdoor kg 34 / 78
Refrigerant Type GWP R32/675
Ref.piping size Liquid/Gas ømm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max.50
Vertical height differences Outdoor is higher/lower m Max.50 / Max.15
Outdoor operating temperature range Cooling*2 °C -15~50
Heating °C -20~20
Air filter, Q'ty (Option) Filter kit : UM-FL2EF
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down
  4. : The values are for one indoor unit operation. (Multi system only)
  5. : In case of following conditions:Max.50m(Outdoor unit is higher & Outdoor temperature 43°C), Max.30m(Outdoor unit is higher & Outdoor temperature > 43°C).