FDUM100VSAPVH

10.0 ( 4.0 ~ 11.2 ) Low Static Pressure Duct Connected Multi Split PAC

FDUM100VSAPVH

Low Static Pressure Duct Connected : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - FDUM50VH x 2 / Outdoor Unit - FDC100VSA
Nominal cooling capacity of 10.0kW

R410A
  • FDUM50VH x 2
  • FDUM50VH x 2

    Indoor Unit : FDUM50VH x 2

    FDC100VSA

    Outdoor Unit : FDC100VSA

  • FDC100VSA
Indoor unitFDUM50VH x 2
Outdoor unitFDC100VSA
Power source3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min-Max)kW10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min-Max)kW11.2 ( 4.0 ~ 12.5 )
Power ConsumptionCooling/HeatingkW3.25 / 3.21
EER/COPCooling/HeatingkW3.08 / 3.49
Inrush currentA5
Max. currentA17
Sound power level*1Indoor*3Cooling/HeatingdB(A)60 / 60
OutdoorCooling/Heating70 / 70
Sound pressure
level*1
Indoor*3Cooling (P-Hi/Hi/Me/Lo)37 / 32 / 29 / 26
Heating (P-Hi/Hi/Me/Lo)37 / 32 / 29 / 26
OutdoorCooling/Heating54 / 56
Air flowIndoor*3Cooling (P-Hi/Hi/Me/Lo)m3/min13 / 10 / 9 / 8
Heating (P-Hi/Hi/Me/Lo)13 / 10 / 9 / 8
OutdoorCooling/Heating75 / 73
External static pressurePaStandard:35 Max:100
Exterior
dimensions
IndoorHeightxWidthxDepthmm280 x 750 x 635
Outdoormm845 x 970 x 370
Net weightIndoor/Outdoorkg29 / 82
Refrigerant chargekg/TCO2Eq3.8/7.934
Refrigerant Type GWPR410A/2088
Ref.piping sizeLiquid/Gasømm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.50
Vertical height differencesOutdoor is higher/lowermMax.50 / Max.15
Outdoor operating temperature rangeCooling*2°C-15~50
Heating°C-20~20
Air filter, Q'ty(Option) Filter kit : UM-FL1EF
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
Energy Class (Cooling/Heating)A/A
SEER5.50
SCOP (Average climate)3.94
Pdesign (cooling/heating(@-10°C))10.0/8.5
Annual Electricity Consumption637/3024
Designated Heating SeasonAverage
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down
  4. : The values are for one indoor unit operation. (Multi system only)