FDU71VNPWVH

7.1 ( 1.5 ~ 7.3 ) High Static Pressure Duct Connected Single Split PAC

FDU71VNPWVH

High Static Pressure Duct Connected : 7.1 ( 1.5 ~ 7.3 )

Indoor Unit - FDU71VH / Outdoor Unit - FDC71VNP-W
Nominal cooling capacity of 7.1kW

R32
  • FDU71VH
  • FDU71VH

    Indoor Unit : FDU71VH

    FDC71VNP-W

    Outdoor Unit : FDC71VNP-W

  • FDC71VNP-W
Indoor unitFDU71VH
Outdoor unitFDC71VNP-W
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW7.1 ( 1.5 ~ 7.3 )
Nominal heating capacity (Min~Max)kW7.1 ( 1.1 ~ 7.3 )
Power consumptionCooling/HeatingkW2.60 / 1.89
EER/COPCooling/Heating2.73. / 3.76
Inrush currentA5
Max. running currentA15.8
Sound power
level*1
Indoor *3Cooling/HeatingdB(A)65 / 65
OutdoorCooling/Heating67 / 67
Sound pressure
level*1
Indoor *3Cooling (Hi/Me/Lo/Ulo)38 / 33 / 29 / 25
Heating (Hi/Me/Lo/Ulo)38 / 33 / 29 / 25
OutdoorCooling/Heating54 / 54
Air flowIndoor *3Cooling (Hi/Me/Lo/Ulo)m3/min24 / 19 / 15 / 10
Heating (Hi/Me/Lo/Ulo)24 / 19 / 15 / 10
OutdoorCooling/Heating42 / 42
Available external static pressurePaStandard:35 Max:200
Exterior DimensionsIndoorHeight x Width x Depthmm280 x 950 x 635
Outdoor640 x 800(+71) x 290
Net weightIndoor / Outdoorkg34 / 45
RefrigerantType/GWPR32/675
RefrigerantChargekg/TCO2Eq1.3/0.878
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) lengthmMax.30
Vertical height differencesOutdoor is higher/lowermMax.20 / Max.20
Outdoor operating
temperature range
Cooling*2°C-15~46
Heating-15~20
Air filter quantityProcure locally
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
Energy Class (Cooling/Heating)A+/A+
SEER5.86
SCOP (Average climate)4.12
Pdesign (cooling/heating(@-10°C))kW7.1/5.7
Annual Electricity Consumption (cooling/heating)kWh/a425/1937
Designated Heating SeasonAverage
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.