FDU200VSAWVH

20.0 ( 7.2 ~ 22.4 ) High Static Pressure Duct Connected Single Split PAC

FDU200VSAWVH

High Static Pressure Duct Connected : 20.0 ( 7.2 ~ 22.4 )

Indoor Unit - FDU200VH / Outdoor Unit - FDC200VSA-W
Nominal cooling capacity of 20.0kW

R32
  • FDU200VH
  • FDU200VH

    Indoor Unit : FDU200VH

    FDC200VSA-W

    Outdoor Unit : FDC200VSA-W

  • FDC200VSA-W
Indoor unitFDU200VH
Outdoor unitFDC200VSA-W
Power source3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min~Max)kW20.0 ( 7.2 ~ 22.4 )
Nominal heating capacity (Min~Max)kW22.4 (6.5 ~ 25.0 )
Power consumptionCooling/HeatingkW6.15 / 5.67
EER/COPCooling/Heating3.25 / 3.95
Inrush currentA5
Max. running currentA23
Sound power
level*1
Indoor *3Cooling/HeatingdB(A)78 / 78
OutdoorCooling/Heating72 / 74
Sound pressure
level*1
Indoor *3Cooling (Hi/Me/Lo/Ulo)52 / 50 / 47 / 45
Heating (Hi/Me/Lo/Ulo)52 / 50 / 47 / 44
OutdoorCooling/Heating58 / 59
Air flowIndoor *3Cooling (Hi/Me/Lo/Ulo)m3/min80 / 72 / 64 / 56
Heating (Hi/Me/Lo/Ulo)80 / 72 / 64 / 56
OutdoorCooling/Heating148 / 134
Exterior DimensionsIndoorHeight x Width x Depthmm379 x 1,600 x 893
Outdoor1,505 x 970 x 370
Net weightIndoor / Outdoorkg88 / 144
RefrigerantType/GWPR32/675
Refrigerant piping sizeLiquid/Gasø mm9.52(3/8") / 22.22(7/8")
Refrigerant line (one way) lengthmMax.70
Vertical height differencesOutdoor is higher/lowermMax.50 / Max.15
Outdoor operating
temperature range
Cooling*2°C-15~50
Heating-20~20
Air filter quantityProcure locally
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
SEER
SCOP (Average climate)
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.