FDU140VSXVH

14.0 ( 5.0 ~ 16.0 ) High Static Pressure Duct Connected Single Split PAC

FDU140VSXVH

High Static Pressure Duct Connected : 14.0 ( 5.0 ~ 16.0 )

Indoor Unit - FDU140VH / Outdoor Unit - FDC140VSX
Nominal cooling capacity of 14.0kW

R410A
  • FDU140VH
  • FDU140VH

    Indoor Unit : FDU140VH

    FDC140VSX

    Outdoor Unit : FDC140VSX

  • FDC140VSX
Indoor unitFDU140VH
Outdoor unitFDC140VSX
Power source3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min~Max)kW14.0 ( 5.0 ~ 16.0 )
Nominal heating capacity (Min~Max)kW16.0 ( 4.0 ~ 20.0 )
Power consumptionCooling/HeatingkW4.28 / 4.42
EER/COPCooling/Heating3.27 / 3.62
Inrush currentA5
Max. running currentA19
Sound power
level*1
Indoor *3Cooling/HeatingdB(A)70 / 70
OutdoorCooling/Heating72 / 72
Sound pressure
level*1
Indoor *3Cooling (Hi/Me/Lo/Ulo)47 / 40 / 35 / 30
Heating (Hi/Me/Lo/Ulo)47 / 40 / 35 / 30
OutdoorCooling/Heating49 / 52
Air flowIndoor *3Cooling (Hi/Me/Lo/Ulo)m3/min48 / 35 / 28 / 22
Heating (Hi/Me/Lo/Ulo)48 / 35 / 28 / 22
OutdoorCooling/Heating100 / 100
Available external static pressurePaStandard:60 Max:200
Exterior DimensionsIndoorHeight x Width x Depthmm280 x 1,370 x 740
Outdoor1,300 x 970 x 370
Net weightIndoor / Outdoorkg54 / 105
RefrigerantType/GWPR410A/2088
Refrigerant piping sizeLiquid/Gasø mm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.100
Vertical height differencesOutdoor is higher/lowermMax.30 / Max.15
Outdoor operating
temperature range
Cooling*2°C-15~43
Heating-20~20
Air filter quantityProcure locally
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
SEER5.36
SCOP (Average climate)3.88
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.