×

FDU100VSXVH

10.0 ( 4.0 ~ 11.2 ) High Static Pressure Duct Connected Single Split PAC

FDU100VSXVH

High Static Pressure Duct Connected : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - FDU100VH / Outdoor Unit - FDC100VSX
Nominal cooling capacity of 10.0kW

R410A
  • FDU100VH
  • FDU100VH

    Indoor Unit : FDU100VH

    FDC100VSX

    Outdoor Unit : FDC100VSX

  • FDC100VSX
Indoor unitFDU100VH
Outdoor unitFDC100VSX
Power source3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min~Max)kW10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min~Max)kW11.2 ( 4.0 ~ 16.0 )
Power consumptionCooling/HeatingkW2.68 / 3.02
EER/COPCooling/Heating3.73 / 3.71
Inrush currentA5
Max. running currentA16
Sound power
level*1
Indoor *3Cooling/HeatingdB(A)65 / 65
OutdoorCooling/Heating70 / 70
Sound pressure
level*1
Indoor *3Cooling (Hi/Me/Lo/Ulo)44 / 38 / 36 / 30
Heating (Hi/Me/Lo/Ulo)44 / 38 / 36 / 30
OutdoorCooling/Heating48 / 50
Air flowIndoor *3Cooling (Hi/Me/Lo/Ulo)m3/min36 / 28 / 25 / 19
Heating (Hi/Me/Lo/Ulo)36 / 28 / 25 / 19
OutdoorCooling/Heating100 / 100
Available external static pressurePaStandard:60 Max:200
Exterior DimensionsIndoorHeight x Width x Depthmm280 x 1,370 x 740
Outdoor1,300 x 970 x 370
Net weightIndoor / Outdoorkg54 / 105
RefrigerantType/GWPR410A/2088
RefrigerantChargekg/TCO2Eq4.5/9.396
Refrigerant piping sizeLiquid/Gasø mm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.100
Vertical height differencesOutdoor is higher/lowermMax.30 / Max.15
Outdoor operating
temperature range
Cooling*2°C-15~43
Heating-20~20
Air filter quantityProcure locally
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-KIT4-E2
Energy Class (Cooling/Heating)A/A+
SEER5.19
SCOP (Average climate)4.10
Pdesign (cooling/heating(@-10°C))kW10.0/13.0
Annual Electricity Consumption (cooling/heating)kWh/a675/4443
Designated Heating SeasonAverage
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level become 5dB(A) higher at external static pressure of 200Pa
  3. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.