FDTC60ZSXW1VH

5.6 ( 1.1 ~ 6.3 ) Compact Ceiling Cassette Single Split PAC

FDTC60ZSXW1VH

Compact Ceiling Cassette : 5.6 ( 1.1 ~ 6.3 )

Indoor Unit - FDTC60VH / Outdoor Unit - SRC60ZSX-W1
Nominal cooling capacity of 5.6kW

R32
  • FDTC60VH
  • FDTC60VH

    Indoor Unit : FDTC60VH

    SRC60ZSX-W1

    Outdoor Unit : SRC60ZSX-W1

  • SRC60ZSX-W1
Indoor unit FDTC60VH
Outdoor unit SRC60ZSX-W1
Power source 1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 5.6 ( 1.1 ~ 6.3 )
Nominal heating capacity (Min~Max) kW 6.7 ( 0.6 ~ 6.7 )
Power consumption Cooling/Heating kW 1.73 / 2.14
EER/COP Cooling/Heating 3.23 / 3.13
Inrush current A 5
Max. running current A 15
Sound power
level*1
Indoor Cooling/Heating dB(A) 60 / 60
Outdoor Cooling/Heating 65 / 65
Sound pressure
level*1
Indoor Cooling (Hi/Me/Lo/Ulo) 46 / 42 / 38 / 31
Heating (Hi/Me/Lo/Ulo) 46 / 42 / 38 / 31
Outdoor Cooling/Heating 53 / 54
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 14 / 12 / 10 / 8
Heating (Hi/Me/Lo/Ulo) 14 / 12 / 10 / 8
Outdoor Cooling/Heating 41.5 / 39
Exterior Dimensions Indoor Height x Width x Depth mm Unit: 248 x 570 x 570 Panel: 10 x 620 x 620
Outdoor 640 x 800(+71) x 290
Net weight Indoor / Outdoor kg 16.5(Unit:14 Standard Panel:2.5) / 45
Refrigerant Type/GWP R32/675
Refrigerant Charge kg/TCO2Eq 1.30/0.878
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) length m Max.30
Vertical height differences Outdoor is higher/lower m Max.20 / Max.20
Outdoor operating
temperature range
Cooling*2 °C -15~46
Heating -20~20
Panel TC-PSA-5AW-E, TC-PSAE-5AW-E(Honeycomb) / TC-PSAG-5AW-E, TC-PSAGE-5AW-E(Grid)
Air filter quantity Pocket plastic net x 1(Washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-TC-5AW-E2, -E3
Energy Class (Cooling/Heating) A++/A+
SEER 6.45
SCOP (Average climate) 4.10
Pdesign (cooling/heating(@-10°C)) kW 5.6/5.1
Annual Electricity Consumption (cooling/heating) kWh/a 304/1744
Designated Heating Season Average
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.