| Indoor unit | FDTC50VH | ||||
| Outdoor unit | SRC50ZSX-W3 | ||||
| Power source | 1Phase, 220 - 240, 50Hz | ||||
| Nominal cooling capacity (Min~Max) | kW | 5.0 ( 1.1 ~ 5.6 ) | |||
| Nominal heating capacity (Min~Max) | kW | 5.4 ( 0.6 ~ 6.3 ) | |||
| Power consumption | Cooling/Heating | kW | 1.40 / 1.53 | ||
| EER/COP | Cooling/Heating | 3.58 / 3.53 | |||
| Max. running current | A | 15 | |||
| Sound power level | Indoor | Cooling/Heating | dB(A) | 59 / 59 | |
| Outdoor | Cooling/Heating | 63 / 62 | |||
| Sound pressure level | Indoor | Cooling (Hi/Me/Lo/Ulo) | 44 / 40 / 35 / 27 | ||
| Heating (Hi/Me/Lo/Ulo) | 44 / 40 / 35 / 27 | ||||
| Outdoor | Cooling/Heating | 52 / 50 | |||
| Air flow | Indoor | Cooling (Hi/Me/Lo/Ulo) | m3/min | 13 / 11 / 9 / 7 | |
| Heating (Hi/Me/Lo/Ulo) | 13 / 11 / 9 / 8 | ||||
| Outdoor | Cooling/Heating | 39 / 33 | |||
| Exterior Dimensions | Indoor | Height x Width x Depth | mm | Unit : 248 x 570 x 570 Panel : 10 x 620 x 620 | |
| Outdoor | 640 x 800(+71) x 290 | ||||
| Net weight | Indoor / Outdoor | kg | 16.5 (Unit : 14 Panel : 2.5 ) / 45.0 | ||
| Refrigerant | Type/GWP | R32/675 | |||
| Refrigerant | Charge | kg/TCO2Eq | 1.30 / 0.878 | ||
| Refrigerant piping size | Liquid/Gas | mm (⌀ inch) | 6.35(1/4") / 12.7(1/2") | ||
| Refrigerant line (one way) length | m | Max. 30 | |||
| Vertical height differences | Outdoor is higher/lower | m | Max. 20 / Max.20 | ||
| Outdoor operating temperature range | Cooling | °C | -15~46 | ||
| Heating | -20~24 | ||||
| Panel | TC-PSA-5AW-E, TC-PSAE-5AW-E (Honeycomb) / TC-PSAG-5AW-E, TC-PSAGE-5AW-E (Grid) | ||||
| Energy Class (Cooling/Heating) | A++/A+ | ||||
| SEER | 6.52 | ||||
| SCOP (Average climate) | 4.30 | ||||
| Pdesign (cooling/heating(@-10°C)) | kW | 5.0/4.3 | |||
| Annual Electricity Consumption (cooling/heating) | kWh/a | 269/1401 | |||
| Designated Heating Season | Average | ||||
• The data is measured under the following conditions(ISO-T1, H1). Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.
• Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
• 'tonne(s) of CO2 equivalent' means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.
*1 The maximum external static pressure can be used up to 35Pa (25•35ZS) , 50Pa (50 •60ZS), but the airflow will be reduced.