×

FDTC125VNXPVH

12.5 ( 5.0 ~ 14.0 ) Compact Ceiling Cassette Multi Split PAC

FDTC125VNXPVH

Compact Ceiling Cassette : 12.5 ( 5.0 ~ 14.0 )

Indoor Unit - FDTC60VH x 2 / Outdoor Unit - FDC125VNX
Nominal cooling capacity of 12.5kW

R410A
  • FDTC60VH x 2
  • FDTC60VH x 2

    Indoor Unit : FDTC60VH x 2

    FDC125VNX

    Outdoor Unit : FDC125VNX

  • FDC125VNX
Indoor unitFDTC60VH x 2
Outdoor unitFDC125VNX
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min-Max)kW12.5 ( 5.0 ~ 14.0 )
Nominal heating capacity (Min-Max)kW14.0 ( 4.0 ~ 17.0 )
Power ConsumptionCooling/HeatingkW4.10 / 4.10
EER/COPCooling/HeatingkW3.05 / 3.41
Inrush currentA5
Max. currentA24
Sound power level*1Indoor*3Cooling/HeatingdB(A)60 / 60
OutdoorCooling/Heating70 / 70
Sound pressure
level*1
Indoor*3Cooling (P-Hi/Hi/Me/Lo)46 / 42 / 38 / 31
Heating (P-Hi/Hi/Me/Lo)46 / 42 / 38 / 31
OutdoorCooling/Heating48 / 50
Air flowIndoor*3Cooling (P-Hi/Hi/Me/Lo)m3/min14 / 12 / 10 / 8
Heating (P-Hi/Hi/Me/Lo)14 / 12 / 10 / 8
OutdoorCooling/Heating100 / 100
Exterior
dimensions
IndoorHeightxWidthxDepthmmUnit: 248 x 570 x 570 Panel: 10 x 620 x 620
Outdoormm1,300 x 970 x 370
Net weightIndoor/Outdoorkg16.5(Unit:14 Standard Panel:2.5) / 105
Refrigerant Type GWPR410A / 2088
Ref.piping sizeLiquid/Gasømm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.100
Vertical height differencesOutdoor is higher/lowermMax.30 / Max.15
Outdoor operating temperature rangeCooling*2°C-15~43
Heating°C-20~20
PanelTC-PSA-5AW-E, TC-PSAE-5AW-ETC-PSA-5AW-E, TC-PSAE-5AW-E(Honeycomb) / TC-PSAG-5AW-E, TC-PSAGE-5AW-E(Grid)
Air filter, Q'tyPocket plastic net x 1(Washable)
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3, wireless:RCN-TC-5AW-E2, -E3
The data is measured under the following conditions (ISO-T1, -H1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down
  3. : The values are for one indoor unit operation. (Multi system only)