FDTC100VSXPVH

10.0 ( 4.0 ~ 11.2 ) Compact Ceiling Cassette Multi Split PAC

FDTC100VSXPVH

Compact Ceiling Cassette : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - FDTC50VH x 2 / Outdoor Unit - FDC100VSX
Nominal cooling capacity of 10.0kW

R410A
  • FDTC50VH x 2
  • FDTC50VH x 2

    Indoor Unit : FDTC50VH x 2

    FDC100VSX

    Outdoor Unit : FDC100VSX

  • FDC100VSX
Indoor unit FDTC50VH x 2
Outdoor unit FDC100VSX
Power source 3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min-Max) kW 10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min-Max) kW 11.2 ( 4.0 ~ 16.0 )
Power Consumption Cooling/Heating kW 2.80 / 3.50
EER/COP Cooling/Heating kW 3.57 / 3.20
Inrush current A 5
Max. current A 15
Sound power level*1 Indoor*3 Cooling/Heating dB(A) 59 / 59
Outdoor Cooling/Heating 70 / 70
Sound pressure
level*1
Indoor*3 Cooling (P-Hi/Hi/Me/Lo) 44 / 40 / 35 / 27
Heating (P-Hi/Hi/Me/Lo) 44 / 40 / 35 / 27
Outdoor Cooling/Heating 48 / 50
Air flow Indoor*3 Cooling (P-Hi/Hi/Me/Lo) m3/min 13 / 11 / 9 / 7
Heating (P-Hi/Hi/Me/Lo) 13 / 11 / 9 / 7
Outdoor Cooling/Heating 100 / 100
Exterior
dimensions
Indoor HeightxWidthxDepth mm Unit: 248 x 570 x 570 Panel: 10 x 620 x 620
Outdoor mm 1,300 x 970 x 370
Net weight Indoor/Outdoor kg 16.5(Unit:14 Standard Panel:2.5) / 105
Refrigerant charge kg/TCO2Eq 4.5/9.396
Refrigerant Type GWP R410A/2088
Ref.piping size Liquid/Gas ømm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max.100
Vertical height differences Outdoor is higher/lower m Max.30 / Max.15
Outdoor operating temperature range Cooling*2 °C -15~43
Heating °C -20~20
Panel TC-PSA-5AW-E, TC-PSAE-5AW-E(Honeycomb) / TC-PSAG-5AW-E, TC-PSAGE-5AW-E(Grid)
Air filter, Q'ty Pocket plastic net x 1(Washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3, wireless:RCN-TC-5AW-E2, -E3
Energy Class (Cooling/Heating) A/A
SEER 5.56
SCOP (Average climate) 3.87
Pdesign (cooling/heating(@-10°C)) 10.0/10.8
Annual Electricity Consumption 630/3910
Designated Heating Season Average
The data is measured under the following conditions (ISO-T1, -H1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down
  3. : The values are for one indoor unit operation. (Multi system only)