×

FDT90VNPVH

9.0 ( 1.9 ~ 9.0 ) Ceiling Cassette Single Split PAC

FDT90VNPVH

Ceiling Cassette : 9.0 ( 1.9 ~ 9.0 )

Indoor Unit - FDT100VH / Outdoor Unit - FDC90VNP1
Nominal cooling capacity of 9.0kW

R410A
  • FDT100VH
  • FDT100VH

    Indoor Unit : FDT100VH

    FDC90VNP1

    Outdoor Unit : FDC90VNP1

  • FDC90VNP1
Indoor unitFDT100VH
Outdoor unitFDC90VNP1
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW9.0 ( 1.9 ~ 9.0 )
Nominal heating capacity (Min~Max)kW9.0 ( 1.5 ~ 9.0 )
Power consumptionCooling/HeatingkW2.67 / 2.19
EER/COPCooling/Heating3.37 / 4.11
Inrush currentA5
Max. running currentA18.0
Sound power
level*1
IndoorCooling/HeatingdB(A)62 / 62
OutdoorCooling/Heating69 / 69
Sound pressure
level*1
IndoorCooling (Hi/Me/Lo/Ulo)47 / 39 / 36 / 30
Heating (Hi/Me/Lo/Ulo)47 / 39 / 36 / 29
OutdoorCooling/Heating57 / 55
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min37 / 26 / 23 / 17
Heating (Hi/Me/Lo/Ulo)37 / 26 / 23 / 17
OutdoorCooling/Heating63 / 49.5
Exterior DimensionsIndoorHeight x Width x DepthmmUnit: 298 x 840 x 840 Panel: 35 x 950 x 950
Outdoor750 x 880(+88) x 340
Net weightIndoor / Outdoorkg30(Unit:25 Standard Panel:5) / 57
RefrigerantType/GWPR410A/2088
RefrigerantChargekg/TCO2Eq2.1/4.385
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.30
Vertical height differencesOutdoor is higher/lowermMax.20 / Max.20
Outdoor operating
temperature range
Cooling*2°C-15~46
Heating-15~20
PanelT-PSA-5BW-E, T-PSAE-5BW-E (White) / T-PSA-5BB-E, T-PSAE-5BB-E (Black)
Air filter quantityPocket Plastic net x 1(Washable)
Remote control (option)wired: RC-EX3A, RC-E5, RCH-E3 wireless: RCN-T-5BW-E2, RCN-T-5BB-E2
Energy Class (Cooling/Heating)A++/A+
SEER6.78
SCOP (Average climate)4.12
Pdesign (cooling/heating(@-10°C))kW9.0/8.1
Annual Electricity Consumption (cooling/heating)kWh/a465/2756
Designated Heating SeasonAverage
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.