×

FDT40ZSXVH

4.0 ( 1.1 ~ 4.7 ) Ceiling Cassette Single Split PAC

FDT40ZSXVH

Ceiling Cassette : 4.0 ( 1.1 ~ 4.7 )

Indoor Unit - FDT40VH / Outdoor Unit - SRC40ZSX-S
Nominal cooling capacity of 4.0kW

R410A
  • FDT40VH
  • FDT40VH

    Indoor Unit : FDT40VH

    SRC40ZSX-S

    Outdoor Unit : SRC40ZSX-S

  • SRC40ZSX-S
Indoor unitFDT40VH
Outdoor unitSRC40ZSX-S
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW4.0 ( 1.1 ~ 4.7 )
Nominal heating capacity (Min~Max)kW4.5 ( 0.6 ~ 5.4 )
Power consumptionCooling/HeatingkW0.93 / 1.03
EER/COPCooling/Heating4.30 / 4.37
Inrush currentA5
Max. running currentA12
Sound power
level*1
IndoorCooling/HeatingdB(A)50 / 50
OutdoorCooling/Heating63 / 63
Sound pressure
level*1
IndoorCooling (Hi/Me/Lo/Ulo)36 / 33 / 30 / 26
Heating (Hi/Me/Lo/Ulo)36 / 33 / 28 / 20
OutdoorCooling/Heating50 / 49
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min19 / 16 / 13 / 10
Heating (Hi/Me/Lo/Ulo)19 / 16 / 13 / 10
OutdoorCooling/Heating36 / 33
Exterior DimensionsIndoorHeight x Width x DepthmmUnit: 236 x 840 x 840 Panel: 35 x 950 x 950
Outdoor640 x 800(+71) x 290
Net weightIndoor / Outdoorkg24(Unit:19 Standard Panel:5) / 45
RefrigerantType/GWPR410A/2088
RefrigerantChargekg/TCO2Eq1.5/3.132
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) lengthmMax.30
Vertical height differencesOutdoor is higher/lowermMax.20 / Max.20
Outdoor operating
temperature range
Cooling*2°C-15~46
Heating-20~24
PanelT-PSA-5BW-E, T-PSAE-5BW-E(White) / T-PSA-5BB-E, T-PSAE-5BB-E(Black)
Air filter quantityPocket plastic net x 1(Washable)
Remote control (option) wired: RC-EX3A, RC-E5, RCH-E3 wireless: RCN-T-5BW-E2, RCN-T-5BB-E2
Energy Class (Cooling/Heating)A+++/A+
SEER8.51
SCOP (Average climate)4.47
Pdesign (cooling/heating(@-10°C))kW4.0/3.8
Annual Electricity Consumption (cooling/heating)kWh/a165/1192
Designated Heating SeasonAverage
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  3. : The values are for one indoor unit operation. (Multi system only)