FDT140VNXVH

14.0 ( 5.0 ~ 16.0 ) Ceiling Cassette Single Split PAC

FDT140VNXVH

Ceiling Cassette : 14.0 ( 5.0 ~ 16.0 )

Indoor Unit - FDT140VH / Outdoor Unit - FDC140VNX
Nominal cooling capacity of 14.0kW

R410A
  • FDT140VH
  • FDT140VH

    Indoor Unit : FDT140VH

    FDC140VNX

    Outdoor Unit : FDC140VNX

  • FDC140VNX
Indoor unit FDT140VH
Outdoor unit FDC140VNX
Power source 1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 14.0 ( 5.0 ~ 16.0 )
Nominal heating capacity (Min~Max) kW 16.0 ( 4.0 ~ 18.0 )
Power consumption Cooling/Heating kW 4.58 / 4.20
EER/COP Cooling/Heating 3.06 / 3.81
Inrush current A 5
Max. running current A 26
Sound power
level*1
Indoor Cooling/Heating dB(A) 63 / 64
Outdoor Cooling/Heating 72 / 72
Sound pressure
level*1
Indoor Cooling (Hi/Me/Lo/Ulo) 48 / 42 / 39 / 32
Heating (Hi/Me/Lo/Ulo) 48 / 41 / 38 / 31
Outdoor Cooling/Heating 49 / 52
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 38 / 29 / 26 / 19
Heating (Hi/Me/Lo/Ulo) 38 / 29 / 26 / 19
Outdoor Cooling/Heating 100 / 100
Exterior Dimensions Indoor Height x Width x Depth mm Unit: 298 x 840 x 840 Panel: 35 x 950 x 950
Outdoor 1,300 x 970 x 370
Net weight Indoor / Outdoor kg 30(Unit:25 Standard Panel:5) / 105
Refrigerant Type/GWP R410A/2088
Refrigerant piping size Liquid/Gas ø mm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max.100
Vertical height differences Outdoor is higher/lower m Max.30 / Max.15
Outdoor operating
temperature range
Cooling*2 °C -15~43
Heating -20~20
Panel T-PSA-5BW-E, T-PSAE-5BW-E (White) / T-PSA-5BB-E, T-PSAE-5BB-E (Black)
Air filter quantity Pocket plastic net x 1(Washable)
Remote control (option) wired: RC-EX3A, RC-E5, RCH-E3 wireless: RCN-T-5BW-E2, RCN-T-5BB-E2
SEER 5.97
SCOP (Average climate) 4.05
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  3. : The values are for one indoor unit operation. (Multi system only)