×

FDT100VSAPVH

10.0 ( 4.0 ~ 11.2 ) Ceiling Cassette Multi Split PAC

FDT100VSAPVH

Ceiling Cassette : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - FDT50VH x 2 / Outdoor Unit - FDC100VSA
Nominal cooling capacity of 10.0kW

R410A
  • FDT50VH x 2
  • FDT50VH x 2

    Indoor Unit : FDT50VH x 2

    FDC100VSA

    Outdoor Unit : FDC100VSA

  • FDC100VSA
Indoor unitFDT50VH x 2
Outdoor unitFDC100VSA
Power source3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min-Max)kW10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min-Max)kW11.2 ( 4.0 ~ 12.5 )
Power ConsumptionCooling/HeatingkW2.82 / 2.90
EER/COPCooling/HeatingkW3.55 / 3.86
Inrush currentA5
Max. currentA15
Sound power level*1Indoor*3Cooling/HeatingdB(A)55 / 56
OutdoorCooling/Heating70 / 70
Sound pressure
level*1
Indoor*3Cooling (P-Hi/Hi/Me/Lo)41 / 33 / 30 / 26
Heating (P-Hi/Hi/Me/Lo)42 / 33 / 28 / 20
OutdoorCooling/Heating54 / 56
Air flowIndoor*3Cooling (P-Hi/Hi/Me/Lo)m3/min22 / 16 / 13 / 10
Heating (P-Hi/Hi/Me/Lo)22 / 16 / 13 / 10
OutdoorCooling/Heating75 / 73
Exterior
dimensions
IndoorHeightxWidthxDepthmmUnit: 236 x 840 x 840 Panel: 35 x 950 x 950 / 82
Outdoormm845 x 970 x 370
Net weightIndoor/Outdoorkg24(Unit:19 Standard Panel:5) / 82
Refrigerant chargekg/TCO2Eq3.8/7.934
Refrigerant Type GWPR410A/2088
Ref.piping sizeLiquid/Gasømm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax. 50
Vertical height differencesOutdoor is higher/lowermMax.50 / Max.15
Outdoor operating temperature rangeCooling*2°C-15~50
Heating°C-20~20
PanelWhite: T-PSA-5BW-E, T-PSAE-5BW-E / Black: T-PSA-5BB-E, T-PSAE-5BB-E
Air filter, Q'tyPocket plastic net x 1(Washable)
Remote control (option)wired: RC-EX3A, RC-E5, RCH-E3 wireless: RCN-T-5BW-E2, RCN-T-5BB-E2
Energy Class (Cooling/Heating)A++/A+
SEER6.89
SCOP (Average climate)4.47
Pdesign (cooling/heating(@-10°C))10.0/8.5
Annual Electricity Consumption508/2665
Designated Heating SeasonAverage
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down