×

FDT100VSAPVH

10.0 ( 4.0 ~ 11.2 ) Ceiling Cassette Multi Split PAC

FDT100VSAPVH

Ceiling Cassette : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - FDT50VH x 2 / Outdoor Unit - FDC100VSA
Nominal cooling capacity of 10.0kW

R410A
  • FDT50VH x 2
  • FDT50VH x 2

    Indoor Unit : FDT50VH x 2

    FDC100VSA

    Outdoor Unit : FDC100VSA

  • FDC100VSA
Indoor unit FDT50VH x 2
Outdoor unit FDC100VSA
Power source 3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min-Max) kW 10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min-Max) kW 11.2 ( 4.0 ~ 12.5 )
Power Consumption Cooling/Heating kW 2.82 / 2.90
EER/COP Cooling/Heating kW 3.55 / 3.86
Inrush current A 5
Max. current A 15
Sound power level*1 Indoor*3 Cooling/Heating dB(A) 55 / 56
Outdoor Cooling/Heating 70 / 70
Sound pressure
level*1
Indoor*3 Cooling (P-Hi/Hi/Me/Lo) 41 / 33 / 30 / 26
Heating (P-Hi/Hi/Me/Lo) 42 / 33 / 28 / 20
Outdoor Cooling/Heating 54 / 56
Air flow Indoor*3 Cooling (P-Hi/Hi/Me/Lo) m3/min 22 / 16 / 13 / 10
Heating (P-Hi/Hi/Me/Lo) 22 / 16 / 13 / 10
Outdoor Cooling/Heating 75 / 73
Exterior
dimensions
Indoor HeightxWidthxDepth mm Unit: 236 x 840 x 840 Panel: 35 x 950 x 950 / 82
Outdoor mm 845 x 970 x 370
Net weight Indoor/Outdoor kg 24(Unit:19 Standard Panel:5) / 82
Refrigerant charge kg/TCO2Eq 3.8/7.934
Refrigerant Type GWP R410A/2088
Ref.piping size Liquid/Gas ømm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max. 50
Vertical height differences Outdoor is higher/lower m Max.50 / Max.15
Outdoor operating temperature range Cooling*2 °C -15~50
Heating °C -20~20
Panel White: T-PSA-5BW-E, T-PSAE-5BW-E / Black: T-PSA-5BB-E, T-PSAE-5BB-E
Air filter, Q'ty Pocket plastic net x 1(Washable)
Remote control (option) wired: RC-EX3A, RC-E5, RCH-E3 wireless: RCN-T-5BW-E2, RCN-T-5BB-E2
Energy Class (Cooling/Heating) A++/A+
SEER 6.89
SCOP (Average climate) 4.47
Pdesign (cooling/heating(@-10°C)) 10.0/8.5
Annual Electricity Consumption 508/2665
Designated Heating Season Average
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down