×

FDT100VNXVH

10.0 ( 4.0 ~ 11.2 ) Ceiling Cassette Single Split PAC

FDT100VNXVH

Ceiling Cassette : 10.0 ( 4.0 ~ 11.2 )

Indoor Unit - FDT100VH / Outdoor Unit - FDC100VNX
Nominal cooling capacity of 10.0kW

R410A
  • FDT100VH
  • FDT100VH

    Indoor Unit : FDT100VH

    FDC100VNX

    Outdoor Unit : FDC100VNX

  • FDC100VNX
Indoor unitFDT100VH
Outdoor unitFDC100VNX
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW10.0 ( 4.0 ~ 11.2 )
Nominal heating capacity (Min~Max)kW11.2 ( 4.0 ~ 12.5 )
Power consumptionCooling/HeatingkW2.50 / 2.58
EER/COPCooling/Heating4.00 / 4.34
Inrush currentA5
Max. running currentA24
Sound power
level*1
IndoorCooling/HeatingdB(A)62 / 62
OutdoorCooling/Heating70 / 70
Sound pressure
level*1
IndoorCooling (Hi/Me/Lo/Ulo)47 / 39 / 36 / 30
Heating (Hi/Me/Lo/Ulo)47 / 39 / 36 / 29
OutdoorCooling/Heating48 / 50
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min37 / 26 / 23 / 17
Heating (Hi/Me/Lo/Ulo)37 / 26 / 23 / 17
OutdoorCooling/Heating100 / 100
Exterior DimensionsIndoorHeight x Width x DepthmmUnit: 298 x 840 x 840 Panel: 35 x 950 x 950
Outdoor1,300 x 970 x 370
Net weightIndoor / Outdoorkg30(Unit:25 Standard Panel:5) / 105
RefrigerantType/GWPR410A/2088
RefrigerantChargekg/TCO2Eq4.5/9.396
Refrigerant piping sizeLiquid/Gasø mm9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.100
Vertical height differencesOutdoor is higher/lowermMax.30 / Max.15
Outdoor operating
temperature range
Cooling*2°C-15~43
Heating-20~20
PanelT-PSA-5BW-E, T-PSAE-5BW-E (White) / T-PSA-5BB-E, T-PSAE-5BB-E (Black)
Air filter quantityPocket plastic net x 1(Washable)
Remote control (option)wired: RC-EX3A, RC-E5, RCH-E3 wireless: RCN-T-5BW-E2, RCN-T-5BB-E2
Energy Class (Cooling/Heating)A+/A+
SEER5.90
SCOP (Average climate)4.32
Pdesign (cooling/heating(@-10°C))kW10.0/11.2
Annual Electricity Consumption (cooling/heating)kWh/a594/3634
Designated Heating SeasonAverage
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  3. : The values are for one indoor unit operation. (Multi system only)