FDF100VNP1VD2

10.0 ( 2.8 ~ 11.2 ) Floor Standing Single Split PAC

FDF100VNP1VD2

Floor Standing : 10.0 ( 2.8 ~ 11.2 )

Indoor Unit - FDF100VD2 / Outdoor Unit - FDC100VNP
Nominal cooling capacity of 10.0kW

R410A
  • FDF100VD2
  • FDF100VD2

    Indoor Unit : FDF100VD2

    FDC100VNP

    Outdoor Unit : FDC100VNP

  • FDC100VNP
Indoor unit FDF100VD2
Outdoor unit FDC100VNP
Power source 1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 10.0 ( 2.8 ~ 11.2 )
Nominal heating capacity (Min~Max) kW 11.2 ( 2.5 ~ 12.5 )
Power consumption Cooling/Heating kW 3.19 / 3.09
EER/COP Cooling/Heating 3.13 / 3.62
Inrush current A 5
Max. running current A 21.0
Sound power
level*1
Indoor Cooling/Heating dB(A) 65 / 65
Outdoor Cooling/Heating 70 / 70
Sound pressure
level*1
Indoor Cooling (Hi/Me/Lo/Ulo) 54 / 50 / 48 / 44
Heating (Hi/Me/Lo/Ulo) 54 / 50 / 48 / 44
Outdoor Cooling/Heating 57 / 61
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 29 / 26 / 23 / 19
Heating (Hi/Me/Lo/Ulo) 29 / 26 / 23 / 19
Outdoor Cooling/Heating 75 / 79
Exterior Dimensions Indoor Height x Width x Depth mm 1,850 x 600 x 320
Outdoor 845 x 970 x 370
Net weight Indoor / Outdoor kg 52 / 70
Refrigerant Type/GWP R410A/2088
Refrigerant Charge kg/TCO2Eq 2.55/5.324
Refrigerant piping size Liquid/Gas ø mm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max.30
Vertical height differences Outdoor is higher/lower m Max.20 / Max.20
Outdoor operating
temperature range
Cooling*2 °C -15~46
Heating -15~20
Air filter quantity Plastic net x 1(Washable)
Remote control (option) wired:RC-E5 (installed) wireless:RCN-KIT4-E2 (option)
Energy Class (Cooling/Heating) A/A
SEER 5.41
SCOP (Average climate) 3.94
Pdesign (cooling/heating(@-10°C)) kW 10.0/8.1
Annual Electricity Consumption (cooling/heating) kWh/a 647/2875
Designated Heating Season Average
The data is measured under the following conditions (ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.