×

FDE90VNPVH

9.0 ( 1.9 ~ 9.0 ) Ceiling Suspended Single Split PAC

FDE90VNPVH

Ceiling Suspended : 9.0 ( 1.9 ~ 9.0 )

Indoor Unit - FDE100VH / Outdoor Unit - FDC90VNP1
Nominal cooling capacity of 9.0kW

R410A
  • FDE100VH
  • FDE100VH

    Indoor Unit : FDE100VH

    FDC90VNP1

    Outdoor Unit : FDC90VNP1

  • FDC90VNP1
Indoor unitFDE100VH
Outdoor unitFDC90VNP1
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW9.0 ( 1.9 ~ 9.0 )
Nominal heating capacity (Min~Max)kW9.0 ( 1.5 ~ 9.0 )
Power consumptionCooling/HeatingkW2.75 / 2.22
EER/COPCooling/Heating3.27 / 4.05
Inrush currentA5
Max. running currentA18
Sound power
level*1
IndoorCooling/HeatingdB(A)64 / 64
OutdoorCooling/Heating69 / 69
Sound pressure
level*1
IndoorCooling (Hi/Me/Lo/Ulo)48 / 43 / 38 / 34
Heating (Hi/Me/Lo/Ulo)48 / 43 / 38 / 34
OutdoorCooling/Heating57 / 55
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min32 / 26 / 21 / 16.5
Heating (Hi/Me/Lo/Ulo)32 / 26 / 21 / 16.5
OutdoorCooling/Heating63 / 49.5
Exterior DimensionsIndoorHeight x Width x Depthmm250 x 1,620 x 690
Outdoor750 x 880(+88) x 340
Net weightIndoor / Outdoorkg43 / 57
RefrigerantType/GWPR410A/2088
RefrigerantChargekg/TCO2Eq2.1/4.385
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4") / 15.88(5/8")
Refrigerant line (one way) lengthmMax.30
Vertical height differencesOutdoor is higher/lowermMax.20 / Max.20
Outdoor operating
temperature range
Cooling*2°C-15~46
Heating-15~20
Air filter quantityPocket Plastic net x2(Washable)
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-E-E3
Energy Class (Cooling/Heating)A++/A+
SEER6.63
SCOP (Average climate)4.25
Pdesign (cooling/heating(@-10°C))kW9.0/8.2
Annual Electricity Consumption (cooling/heating)kWh/a475/2704
Designated Heating SeasonAverage
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A:ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  3. : The values are for one indoor unit operation. (Multi system only)