FDE71VNXPVH

7.1 ( 3.2 ~ 8.0 ) Ceiling Suspended Multi Split PAC

FDE71VNXPVH

Ceiling Suspended : 7.1 ( 3.2 ~ 8.0 )

Indoor Unit - FDE40VH x 2 / Outdoor Unit - FDC71VNX
Nominal cooling capacity of 7.1kW

R410A
  • FDE40VH x 2
  • FDE40VH x 2

    Indoor Unit : FDE40VH x 2

    FDC71VNX

    Outdoor Unit : FDC71VNX

  • FDC71VNX
Indoor unit FDE40VH x 2
Outdoor unit FDC71VNX
Power source 1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min-Max) kW 7.1 ( 3.2 ~ 8.0 )
Nominal heating capacity (Min-Max) kW 8.0 ( 3.6 ~ 9.0 )
Power Consumption Cooling/Heating kW 2.05 / 2.35
EER/COP Cooling/Heating kW 3.46 / 3.40
Inrush current A 5
Max. current A 17
Sound power level*1 Indoor*3 Cooling/Heating dB(A) 60 / 60
Outdoor Cooling/Heating 66 / 66
Sound pressure
level*1
Indoor*3 Cooling (P-Hi/Hi/Me/Lo) 46 / 38 / 36 / 31
Heating (P-Hi/Hi/Me/Lo) 46 / 38 / 36 / 31
Outdoor Cooling/Heating 51 / 48
Air flow Indoor*3 Cooling (P-Hi/Hi/Me/Lo) m3/min 13 / 10 / 9 / 7
Heating (P-Hi/Hi/Me/Lo) 13 / 10 / 9 / 7
Outdoor Cooling/Heating 60 / 50
Exterior
dimensions
Indoor HeightxWidthxDepth mm 210 x 1,070 x 690
Outdoor mm 750 x 880(+88) x 340
Net weight Indoor/Outdoor kg 28 / 60
Refrigerant charge kg/TCO2Eq 2.95/6.160
Refrigerant Type GWP R410A/2088
Ref.piping size Liquid/Gas ømm 9.52(3/8") / 15.88(5/8")
Refrigerant line (one way) length m Max. 50
Vertical height differences Outdoor is higher/lower m Max.30 / Max.15
Outdoor operating temperature range Cooling*2 °C -15~43
Heating °C -20~20
Air filter, Q'ty Pocket plastic net x2(Washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-E-E3
Energy Class (Cooling/Heating) A/A+
SEER 5.26
SCOP (Average climate) 4.09
Pdesign (cooling/heating(@-10°C)) 7.1/6.0
Annual Electricity Consumption 473/2056
Designated Heating Season Average
The data is measured under the following conditions (ISO-T1, -H1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down
  3. : The values are for one indoor unit operation. (Multi system only)