FDE50ZSXVH

5.0 ( 1.1 ~ 5.6 ) Ceiling Suspended Single Split PAC

FDE50ZSXVH

Ceiling Suspended : 5.0 ( 1.1 ~ 5.6 )

Indoor Unit - FDE50VH / Outdoor Unit - SRC50ZSX-S
Nominal cooling capacity of 5.0kW

R410A
  • FDE50VH
  • FDE50VH

    Indoor Unit : FDE50VH

    SRC50ZSX-S

    Outdoor Unit : SRC50ZSX-S

  • SRC50ZSX-S
Indoor unitFDE50VH
Outdoor unitSRC50ZSX-S
Power source1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max)kW5.0 ( 1.1 ~ 5.6 )
Nominal heating capacity (Min~Max)kW5.4 ( 0.6 ~ 6.3 )
Power consumptionCooling/HeatingkW1.52 / 1.46
EER/COPCooling/Heating3.29 / 3.70
Inrush currentA5
Max. running currentA15
Sound power
level*1
IndoorCooling/HeatingdB(A)60 / 60
OutdoorCooling/Heating63 / 63
Sound pressure
level*1
IndoorCooling (Hi/Me/Lo/Ulo)46 / 38 / 36 / 31
Heating (Hi/Me/Lo/Ulo)46 / 38 / 36 / 31
OutdoorCooling/Heating50 / 49
Air flowIndoorCooling (Hi/Me/Lo/Ulo)m3/min13 / 10 / 9 / 7
Heating (Hi/Me/Lo/Ulo)13 / 10 / 9 / 7
OutdoorCooling/Heating40 / 33
Exterior DimensionsIndoorHeight x Width x Depthmm210 x 1,070 x 690
Outdoor640 x 800(+71) x 290
Net weightIndoor / Outdoorkg28 / 45
RefrigerantType/GWPR410A/2088
RefrigerantChargekg/TCO2Eq1.5/3.132
Refrigerant piping sizeLiquid/Gasø inch6.35(1/4") / 12.7(1/2")
Refrigerant line (one way) lengthmMax.30
Vertical height differencesOutdoor is higher/lowermMax.20 / Max.20
Outdoor operating
temperature range
Cooling*2°C-15~46
Heating-20~24
Air filter quantityPocket Plastic net x2(Washable)
Remote control (option)wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-E-E3
Energy Class (Cooling/Heating)A++/A
SEER6.10
SCOP (Average climate)3.92
Pdesign (cooling/heating(@-10°C))kW5.0/3.8
Annual Electricity Consumption (cooling/heating)kWh/a288/1359
Designated Heating SeasonAverage
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A:ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  3. : The values are for one indoor unit operation. (Multi system only)