FDE250VSAWDVH

25.0 ( 7.8 ~ 28.0 ) Ceiling Suspended Multi Split PAC

FDE250VSAWDVH

Ceiling Suspended : 25.0 ( 7.8 ~ 28.0 )

Indoor Unit - FDE60VH x 4 / Outdoor Unit - FDC250VSA-W
Nominal cooling capacity of 25.0kW

R32
  • FDE60VH x 4
  • FDE60VH x 4

    Indoor Unit : FDE60VH x 4

    FDC250VSA-W

    Outdoor Unit : FDC250VSA-W

  • FDC250VSA-W
Indoor unit FDE60VH x 4
Outdoor unit FDC250VSA-W
Power source 3 Phase 380-415V, 50Hz / 380V, 60Hz
Nominal cooling capacity (Min-Max) kW 25.0 ( 7.8 ~ 28.0 )
Nominal heating capacity (Min-Max) kW 28.0 ( 5.2 ~ 31.5 )
Power Consumption Cooling/Heating kW 8.04 / 7.32
EER/COP Cooling/Heating kW 3.11 / 3.83
Inrush current A 5
Max. current A 20
Sound power level*1 Indoor*3 Cooling/Heating dB(A) 60 / 60
Outdoor Cooling/Heating 73 / 75
Sound pressure
level*1
Indoor*3 Cooling (P-Hi/Hi/Me/Lo) 47 / 41 / 37 / 32
Heating (P-Hi/Hi/Me/Lo) 47 / 41 / 37 / 32
Outdoor Cooling/Heating 58 / 62
Air flow Indoor*3 Cooling (P-Hi/Hi/Me/Lo) m3/min 20 / 16 / 13 / 10
Heating (P-Hi/Hi/Me/Lo) 20 / 16 / 13 / 10
Outdoor Cooling/Heating 148 / 153
Exterior
dimensions
Indoor HeightxWidthxDepth mm 210 x 1,320 x 690
Outdoor mm 1,505 x 970 x 370
Net weight Indoor/Outdoor kg 33 / 145
Refrigerant Type GWP R32/675
Ref.piping size Liquid/Gas ømm 12.7(1/2") / 22.22(7/8")
Refrigerant line (one way) length m Max. 70
Vertical height differences Outdoor is higher/lower m Max.50 / Max.15
Outdoor operating temperature range Cooling*2 °C -15~50
Heating °C -20~20
Air filter, Q'ty Pocket plastic net x 2(Washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-E-E3
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A : ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions
  2. : If a cooling operation is conducted when the outdoor air temperature is —5°C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind, if wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down
  3. : The values are for one indoor unit operation. (Multi system only)
  4. : In case of following conditions:Max.50m(Outdoor unit is higher & Outdoor temperature 43°C), Max.30m(Outdoor unit is higher & Outdoor temperature > 43°C).