FDE100VNPWVH

10.0 ( 2.1 ~ 10.2 ) Ceiling Suspended Single Split PAC

FDE100VNPWVH

Ceiling Suspended : 10.0 ( 2.1 ~ 10.2 )

Indoor Unit - FDE100VH / Outdoor Unit - FDC100VNP-W
Nominal cooling capacity of 10.0kW

R32
  • FDE100VH
  • FDE100VH

    Indoor Unit : FDE100VH

    FDC100VNP-W

    Outdoor Unit : FDC100VNP-W

  • FDC100VNP-W
Indoor unit FDE100VH
Outdoor unit FDC100VNP-W
Power source 1 Phase 220-240V, 50Hz / 220V, 60Hz
Nominal cooling capacity (Min~Max) kW 10.0 ( 2.1 ~ 10.2 )
Nominal heating capacity (Min~Max) kW 10.0 ( 1.7 ~ 10.4 )
Power consumption Cooling/Heating kW 3.00 / 2.36
EER/COP Cooling/Heating 3.33 / 4.24
Inrush current A 5
Max. running current A 19
Sound power
level*1
Indoor Cooling/Heating dB(A) 64 / 64
Outdoor Cooling/Heating 68 / 67
Sound pressure
level*1
Indoor Cooling (Hi/Me/Lo/Ulo) 48 / 43 / 38 / 34
Heating (Hi/Me/Lo/Ulo) 48 / 43 / 38 / 34
Outdoor Cooling/Heating 56 / 54
Air flow Indoor Cooling (Hi/Me/Lo/Ulo) m3/min 32 / 26 / 21 / 16.5
Heating (Hi/Me/Lo/Ulo) 32 / 26 / 21 / 16.5
Outdoor Cooling/Heating 63 / 55
Exterior Dimensions Indoor Height x Width x Depth mm 250 x 1,620 x 690
Outdoor 750 x 880(+88) x 340
Net weight Indoor / Outdoor kg 43 / 57
Refrigerant Type/GWP R32/675
Refrigerant Charge kg/TCO2Eq 1.7/1.148
Refrigerant piping size Liquid/Gas ø mm 6.35(1/4") / 15.88(5/8")
Refrigerant line (one way) length m Max.30
Vertical height differences Outdoor is higher/lower m Max.20 / Max.20
Outdoor operating
temperature range
Cooling*2 °C -15~46
Heating -15~20
Air filter quantity Pocket Plastic net x2(Washable)
Remote control (option) wired:RC-EX3A, RC-E5, RCH-E3 wireless:RCN-E-E3
Energy Class (Cooling/Heating) A++/A+
SEER 6.63
SCOP (Average climate) 4.24
Pdesign (cooling/heating(@-10°C)) kW 10.0/6.0
Annual Electricity Consumption (cooling/heating) kWh/a 529/1984
Designated Heating Season Average
The data is measured under the following conditions (R32 : ISO-T1, -H1 /, R410A:ISO-T1).
Cooling: Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB. Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
  1. : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
  2. : If a cooling operation is conducted when the outdoor air temperature is –5 ̊C or lower, the outdoor unit should be installed at a place where it is not influenced by natural wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
  3. : The values are for one indoor unit operation. (Multi system only)